Major detachment of aortic prosthetic valves.
نویسندگان
چکیده
The clinical and investigatory findings in five instances of major detachment of an aortic valve prosthesis in four patients are described. This situation was associated with auscultatory and peripheral signs of aortic regurgitation and, in addition, a mid-diastolic murmur in the mitral area. From the haemodynamic and operative findings it was postulated that, in addition to severe aortic regurgitation, disturbance of mitral valve function occurred both in systole and diastole caused by the pivoting of the prosthesis attached to the base of the aortic leaflet of the mitral valve. Cardiac fluoroscopy confirmed the diagnosis.
منابع مشابه
مقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی
In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...
متن کاملPregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves
There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...
متن کاملAortic Valve Involvement in Behçet’s Disease. A Clinical Study of 9 Patients
OBJECTIVES To assess the clinical features, pathologic findings, postoperative results and the effects of immunosuppressive therapy in patients with Behçet's disease (BD). METHODS We reviewed the postoperative course of the 9 BD patients who underwent a total of 17 aortic valve replacement procedures with prosthetic valves. RESULTS Histological examination of the aortic valve commonly revea...
متن کاملEvaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.
We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...
متن کاملA New Complication of Swan-Ganz Catheterization
CHEST, 75: 4, APRIL, 1979 PULMONARY ARTERY-BRONCHIAL FISTULA 515 signs in endocarditis following prosthetic valve replacement. J Thorac Cardiovasc Surg 58:554-557, 1968 3 Sutton CC, Wright JEC: Major detachment of aortic prosthetic valves. Br Heart J 32:337-343, 1970 4 Chandraratna PAN, Lopez JM, Hildner FJ, et al: Diagnosis of Bjork-Shiley aorticvalve dysfunction by echocardiography. Am Heart ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 32 3 شماره
صفحات -
تاریخ انتشار 1970