Pyrolytic and non-pyrolytic boron nitride platforms in electrothermal AAS for the determination of cadmium in sea and estuarine water without chemical modification.
نویسندگان
چکیده
The analytical performance of pyrolytic and non-pyrolytic boron nitride (PBN and NBN) platforms, attached to a commercially available graphite tube furnace, in electrothermal atomic absorption spectrometry (ETAAS) for Cd was studied. Although the tolerable pyrolysis temperature was 300 degrees C with the conventional pyrolytic graphite platform, it increased to 600 and 950 degrees C with the PBN and NBN platforms, respectively. The lifetime of the ceramic platform was 500 firings. The NBN platform provided an enhanced sensitivity with a better reproducibility than others. Using the NBN platform allowed the LOD, based on the variability of the blank (3sigma), to be 0.1 microg l(-1) within a seawater matrix (20,000 mg NaCl l(-1)) and a constant sensitivity in the range 0-30,000 mg NaCl l(-1). Good recovery in the range of 90-105% was observed for Cd (2.0 microg l(-1)) spiked into sea, estuarine and river water samples using the recommended procedure. This work proposes that using the NBN platform allows the direct monitoring and control of contaminated water for Cd by ETAAS without any chemical modification.
منابع مشابه
Determination of cadmium in wine by electrothermal atomic absorption spectrometry.
A method is described for direct electrothermal atomic absorption spectrometric (ETAAS) determination of cadmium in untreated samples of wine. Pyrolytic graphite tubes and graphite tubes with standard L'vov pyrolytic platforms were tested as atomizers. The detection limit achieved was 0.08 microg L(-1) Cd in wine. The relative standard deviation for the concentration range from 0.2 to 10 microg...
متن کاملPhotoluminescence properties of pyrolytic boron nitride
We report on spectroscopic study of pyrolytic hBN (pBN) by means of time-and energy-resolved photoluminescence methods. A high purity of pBN samples (though low crystallinity) allows complementary information about excited states involved into the luminescence process. We affirm our recent conclusions about the impurity-related nature of most of the fluorescence bands in microcrystalline hBN. I...
متن کاملLarge-volume injection electrothermal AAS combined with tungsten-treated pyrolytic graphite furnace: determination of cadmium in tap, snow and river water samples with phosphate modifier.
A large-volume (100 microl) injection-ETAAS with W-treated PG furnace combined with a phosphate modifier was applied to the determination of unpolluted levels of Cd in tap, snow and river-water samples. The limit of detection of 1.1 ng l(-1) was observed for a 4 w/v% NH4H2PO4 modifer. Matrix interference studies were tested for major ion species well found in fresh water. The direct determinati...
متن کاملVoltammetric Behavior and Determination of Trace Amounts of Omeprazole Using an Edge-plane Pyrolytic Graphite Electrode
The voltammetric performance of edge-plane pyrolytic graphite (EPG) electrode via adsorptive stripping voltammetry was investigated for study of the electrochemical behavior of omeprazole (OMZ) in aqueous solution. The results revealed that the oxidation of OMZ is an irreversible pH-dependent process that proceeds with the transfer of one electron and one proton in an adsorption-controlled mech...
متن کاملVoltammetric Behavior and Determination of Trace Amounts of Omeprazole Using an Edge-plane Pyrolytic Graphite Electrode
The voltammetric performance of edge-plane pyrolytic graphite (EPG) electrode via adsorptive stripping voltammetry was investigated for study of the electrochemical behavior of omeprazole (OMZ) in aqueous solution. The results revealed that the oxidation of OMZ is an irreversible pH-dependent process that proceeds with the transfer of one electron and one proton in an adsorption-controlled mech...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 20 12 شماره
صفحات -
تاریخ انتشار 2004