Using force spectroscopy analysis to improve the properties of the hairpin probe

نویسندگان

  • Liu Yang
  • Kemin Wang
  • Weihong Tan
  • Huimin Li
  • Xiaohai Yang
  • Changbei Ma
  • Hongxing Tang
چکیده

The sensitivity of hairpin-probe-based fluorescence resonance energy transfer (FRET) analysis was sequence-dependent in detecting single base mismatches with different positions and identities. In this paper, the relationship between the sequence-dependent effect and the discrimination sensitivity of a single base mismatch was systematically investigated by fluorescence analysis and force spectroscopy analysis. The same hairpin probe was used. The uneven fluorescence analysis sensitivity was obviously influenced by the guanine-cytosine (GC) contents as well as the location of the mismatched base. However, we found that force spectroscopy analysis distinguished itself, displaying a high and even sensitivity in detecting differently mismatched targets. This could therefore be an alternative and novel way to minimize the sequence-dependent effect of the hairpin probe. The advantage offered by force spectroscopy analysis could mainly be attributed to the percentage of rupture force reduction, which could be directly and dramatically influenced by the percentage of secondary structure disruption contributed by each mismatched base pair, regardless of its location and identity. This yes-or-no detection mechanism should both contribute to a comprehensive understanding of the sensitivity source of different mutation analyses and extend the application range of hairpin probes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Au nanoparticles/g-C3N4 modified biosensor for electrochemical detection of gastric cancer miRNA based on hairpin locked nucleic acids probe

Objective: The annual incidence of cancer in the world is growing rapidly. The most important factor in the cure of cancers is their early diagnosis. miRNA, as a biomarker for early detection of cancer, has attracted a lot of attention. Methods: In this study, an electrochemical biosensor was developed to detect the amount of miR-106a, the biomarker of gastric cancer, by modifying a glass...

متن کامل

The Effect of Substrate on Structural and Electrical Properties of Cu3N Thin Film by DC Reactive Magnetron Sputtering

The aim of this paper is to study the effect of substrate on the Cu3N thin films. At first Cu3N thin films are prepared using DC magnetron sputtering system. Then structural properties, surface roughness, and electrical resistance are studied using X-ray diffraction (XRD), the atomic force microscope (AFM) and four-point probe techniques respectively. Finally, the results are investigated and c...

متن کامل

Structural and mechanical properties of AFe2O4 (A = Zn, Cu0.5Zn0.5, Ni0.3Cu0.2Zn0.5) nanoparticles prepared by citrate method at low temperature

In this work, the structural and elastic moduli properties of ZnFe2O4, Zn0.5Cu0.5Fe2O4, and Ni0.3Cu0.2Zn0.5Fe2O4 ferrites prepared by the citrate method have been investigated. The structuralcharacterization of the samples is evidence for a cubic structure with Fd-3m space group. TheHalder-Wagner analysis was used to study crystallite sizes and lattice strain and also stressand energy density. ...

متن کامل

Magnetic force microscopy using fabricated cobalt-coated carbon nanotubes probes

Magnetic force microscope ( MFM ) is a powerful technique for mapping the magnetic force gradient above the sample surface. Herein, single-wall carbon nanotubes (SWCNT) were used to fabricate MFM probe by dielectrophoresis method which is a reproducible and cost-effective technique. The effect of induced voltage on the deposition manner of carbon nanotubes (CNT) on the atomic force microscope (...

متن کامل

Effect of Cu Content on TiN-Cu Nanocomposite Film Properties: Structural and Hardness Studies

Titanium nitride-Copper (TiN-Cu) nanocomposite films were deposited onto stainless steel substrate using hollow cathode discharge ion plating technique. The influence of Cu content in the range of 2-7 at.% on the microstructure, morphology and mechanical properties of deposited films were investigated. Structural properties of the films were studied by X-ray diffraction pattern. Topography of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2007