The biomechanical performance of locking plate fixation with intramedullary fibular strut graft augmentation in the treatment of unstable fractures of the proximal humerus.

نویسندگان

  • J-H Bae
  • J-K Oh
  • C-S Chon
  • C-W Oh
  • J-H Hwang
  • Y-C Yoon
چکیده

We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus. Biomechanical testing of the two groups, locking plate alone (LP), and locking plate with a fibular strut graft (LPSG), was performed using seven pairs of human cadaveric humeri. Cyclical loads between 10 N and 80 N at 5 Hz were applied for 1,000,000 cycles. Immediately after cycling, an increasing axial load was applied at a rate of displacement of 5 mm/min. The displacement of the construct, maximum failure load, stiffness and mode of failure were compared. The displacement was significantly less in the LPSG group than in the LP group (p = 0.031). All maximum failure loads and measures of stiffness in the LPSG group were significantly higher than those in the LP group (p = 0.024 and p = 0.035, respectively). In the LP group, varus collapse and plate bending were seen. In the LPSG group, the humeral head cut out and the fibular strut grafts fractured. No broken plates or screws were seen in either group. We conclude that strut graft augmentation significantly increases both the maximum failure load and the initial stiffness of this construct compared with a locking plate alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early outcomes of proximal humerus fracture fixation with locking plate and intramedullary fibular strut graft.

Proximal humerus fractures are commonly encountered in elderly patients. Surgical treatment demonstrates high complication rates, including varus construct collapse and screw cutout. In this study, the authors evaluate the clinical outcome of locking plate fixation with intramedullary fibular strut graft augmentation as a primary surgical treatment in the prevention of early collapse and screw ...

متن کامل

Biomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support

BACKGROUND Comminuted fractures of the proximal humerus are generally treated with the locking plate system, and clinical results are satisfactory. However, unstable support of the medial column results in varus malunion and screw perforation. We designed a novel medial anatomical locking plate (MLP) to directly support the medial column. Theoretically, the combined application of locking plate...

متن کامل

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

Proximal humeral nonunion treated with an intramedullary tantalum cylinder.

Nonunion is uncommon after proximal humerus fracture surgery. There is no agreement about preferred method of treatment. Traditional approaches have included laterally based locking plates, autogenous grafting, and endosteal support to provide improved biomechanical stability. Open reduction and internal fixation (ORIF) of proximal humeral nonunion has been performed with various methods, inclu...

متن کامل

Fibular Strut Graft Augmentation for Open Reduction and Internal Fixation of Proximal Humerus Fractures

BACKGROUND Proximal humerus fractures are common problems plaguing the elderly population. PURPOSE The purposes of this study were to determine the outcomes of fibular strut allografts in treatment of proximal humerus fractures with open reduction internal fixation (ORIF) and to present the authors' preferred surgical technique. The hypothesis was that the use of fibular strut allografts in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 93 7  شماره 

صفحات  -

تاریخ انتشار 2011