Study of retinal nerve fibre layer thickness in eyes with high tension glaucoma and hemifield defect.

نویسندگان

  • M S Kook
  • K Sung
  • S Kim
  • R Park
  • W Kang
چکیده

AIM To quantitatively evaluate retinal nerve fibre layer (RNFL) difference in areas of apparently normal appearing visual field in eyes with high tension glaucoma (HTG) and hemifield defects using scanning laser polarimetry. METHODS 40 eyes from 40 patients with HTG with superior or inferior hemifield defects based on the Humphrey field analyser (HFA) underwent RNFL thickness measurements. 20 normal eyes from 20 subjects matched in age and refractive error were selected as a control group. The RNFL thickness was measured with a scanning laser polarimeter. Mean RNFL thickness was evaluated in four quadrants (superior, inferior, nasal, and temporal). A superior or inferior quadrant in the defined ring of scanning laser polarimetry corresponds to inferior or superior hemifield in HFA. RESULTS The mean RNFL thickness in the unaffected quadrant (the quadrant corresponding to the hemifield with apparently normal visual field based on HFA) of the HTG group was significantly thinner than the average RNFL thickness of the corresponding quadrant of the control eyes. The RNFL thickness of the unaffected quadrant in the eyes with HTG was reduced and statistically similar to that of the affected quadrant. Symmetry, calculated as the ratio of superior to inferior RNFL thickness, showed no statistical difference between the study and control group. CONCLUSION Changes in RNFL are present in the apparently normal hemifield in the eyes with HTG. The thickness of the RNFL is reduced symmetrically in both superior and inferior quadrants based on the GDx parameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Association between Optic Nerve Head Microcirculation and Macular Ganglion Cell Complex Thickness in Eyes with Untreated Normal Tension Glaucoma and a Hemifield Defect

Purpose. We evaluated the association between optic nerve head (ONH) microcirculation and macular ganglion cell complex (mGCC) thickness in patients with untreated normal tension glaucoma (NTG) and a hemifield defect. Methods. The medical records of 47 patients with untreated NTG were retrospectively reviewed. Laser speckle flowgraphy was used to obtain mean blur rate (MBR), a relative measure ...

متن کامل

Study of retinal nerve fiber layer thickness within normal hemivisual field in primary open-angle glaucoma and normal-tension glaucoma.

PURPOSE To determine if nerve fiber layer thickness (NFLT) in glaucoma patients decreases before the development of visual field loss, and if there is a difference in the thinning of NFLT between primary open-angle glaucoma (POAG) and normal-tension glaucoma (NTG) eyes. METHODS Thirty patients (33 eyes) with POAG and 31 patients (31eyes) with NTG, who had visual field defects localized in eit...

متن کامل

Anatomical Attributes of the Optic Nerve Head in Eyes with Parafoveal Scotoma in Normal Tension Glaucoma

PURPOSE To evaluate optic nerve characteristics independent of systemic factors predisposing to parafoveal scotoma in normal tension glaucoma. METHODS We included 40 patients with bilateral normal tension glaucoma with parafoveal scotoma (visual field defect in one hemifield within 10° of fixation with at least one point at p<1% lying at the two innermost paracentral points) in only one eye (...

متن کامل

Evaluation of retinal nerve fiber layer defect using wide-field en-face swept-source OCT images by applying the inner limiting membrane flattening

PURPOSE The assessment of retinal nerve fiber layer defects (RNFLDs) is a useful part of glaucoma care. Here, we obtained en-face images of retinal layers below the inner limiting membrane (ILM) with swept source-optical coherence tomography (SS-OCT), and measured RNFLD angle with new software. METHODS This study included 105 eyes of 105 normal tension glaucoma (NTG) patients (age, 59.8 ± 13....

متن کامل

Transsynaptic retinal degeneration in optic neuropathies: optical coherence tomography study.

PURPOSE Recently demonstrated neuronal loss in the inner nuclear layer of the retina in multiple sclerosis (MS) and glaucoma raises the question of a primary (possibly immune-mediated) or secondary (transsynaptic) mechanism of retinal damage in these diseases. In the present study we used optical coherence tomography to investigate retrograde retinal transsynaptic degeneration in patients with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 85 10  شماره 

صفحات  -