Fabrication and structural characterization of a resonant frequency PZT microcantilever
نویسندگان
چکیده
The fabrication and structural characterization of a surface micromachined, resonant frequency, Pb(Zr, Ti)O3 (PZT) microcantilever will be presented. The PZT microcantilever was fabricated using surface micromachining techniques, and used a low-stress silicon nitride thin film as the base material for the microcantilever onto which a PZT thin film was incorporated. The PZT thin film is used as both the microsensor and the microactuator. A unique fabrication procedure was developed in order to eliminate the step of encapsulating the PZT during the removal of the spacer layer. The encapsulation step was avoided because of the difficulty in finding a suitable material, which would protect the PZT during the removal of the spacer layer yet not affect its material properties. This predicament was resolved by removing the spacer layer prior to the deposition of the PZT. The microcantilevers were characterized extensively using an atomic force microscope in an unusual manner. The atomic force microscope was modified in such a fashion that the deflection at the tip of the microcantilever could be measured as the frequency of an electrical signal applied to the PZT thin film was varied. In addition, an impedance analyzer was used to characterize the microcantilevers. Simple thin-film, laminated plate theory was used to obtain a closed-form solution for the modal response of the microcantilever, while ANSYS was used to obtain modal and harmonic simulation results. It will be shown that the experimental, numerical, and theoretical modal results are within ±10% of one another. The experimental and numerical harmonic results differ by an order of magnitude; however, the numerical model is currently being modified to more accurately represent the PZT microcantilever. From the information gathered during the structural characterization of the PZT microcantilever, it will be shown that certain higher-order resonant frequency modes have very large mechanical responses. These higher-order resonant frequency modes give designers another parameter to adjust when trying to optimize the design of their resonant frequency device. (Some figures in this article are in colour only in the electronic version; see www.iop.org) 5 Author to whom correspondence should be addressed. Present address: Integrated Magnetoelectronics, 2727 26th Ave S, Minneapolis, MN 55406, USA. 0964-1726/01/020252+12$30.00 © 2001 IOP Publishing Ltd Printed in the UK 252 Resonant frequency PZT microcantilever
منابع مشابه
Detection of Group A Streptococcus and Model Protein Using Self-Excited PZT-Glass Microcantilever
A composite self-excited PZT-glass cantilever (4mm in length and 2mm width) was fabricated and used to measure attachment of model protein and a model pathogen. Key feature of the microcantilever is that its resonant frequency is dependent on its mass. The cantilever had a mass sensitivity of 5x10-11 g/Hz. The change in resonant frequency was measured as antibody, protein, reacts with the amine...
متن کاملStudy of the size-dependant vibration behavior of an AFM microcantilever with a sidewall probe
In this paper, the resonant frequency and sensitivity of an atomic force microscope (AFM) with an assembled cantilever probe (ACP) are analyzed utilizing the modified couple stress theory. The proposed ACP comprises a horizontal microcantilever, an extension and a tip located at the free end of the extension, which make AFM capable of scanning the sample sidewall. First, the governing different...
متن کاملSol-Gel Synthesis and Piezoelectric and Structural Properties of Zr –rich PZT Nanoparticles
Lead zirconate titanate (PZT) nanopowders with spherical-shaped morphology, perovskite structure and an average size of 20 nm were successfully synthesized. The prepared PZT nanopowders were characterized by differential thermal analysis (DTA), X-ray diffraction (XRD), scanning electron microscopy (SEM), Energy dispersive X-ray (EDS) and Transmission electron microscopy (TEM) technique. Single-...
متن کاملDesign, Fabrication and Experimental-Numerical Study of PZT Sensors
MEMS micropumps, based on PZT membranes have been designed and fabricated at the Microtechnology Laboratory of the University of Minnesota for use in fluid flow control, and as chemical and pressure sensors. Design, fabrication and numerical analyses of the PZT cantilever beams were presented at the MSM99, and are now extended to new MEMS devices; specifically reactive ion etched (RIE) bulk mic...
متن کاملAnalysis of DNA hybridization regarding the conformation of molecular layer with piezoelectric microcantilevers.
Lead Zirconate Titanate (PZT)-embedded microcantilevers were fabricated with dimensions of 30 × 90 × 3 μm(3) (width × length × thickness). A thicker PZT layer improved the actuation and enabled long-term data acquisition in common aqueous buffers with a frequency resolution of 20 Hz. A quantitative assay was conducted in the range of 1-20 μM and the resonant frequency was found to increase with...