Endovascular techniques and procedures, methods for removal of intravascular foreign bodies.
نویسندگان
چکیده
INTRODUCTION The incidence of intravascular embolization of venous catheters reported in the world medical literature corresponds to 1% of all the described complications. However, its mortality rate may vary between 24 to 60%. Catheter malfunction is the most likely signal of embolization, since patients are usually asymptomatic. OBJECTIVE To report the method of removing intravascular foreign bodies, catheters with the use of various endovascular techniques and procedures. METHODS This is a two-year retrospective study of 12 patients: seven women and five men. The average age was 29 years (ranging from two months to 65 years). RESULTS Technical performance was 100% successful. Ten port-a-caths, one intra-cath and one PICC were extracted. The most common sites for the lodging of one of the ends of the intravascular foreign bodies were the right atrium (41.6%) and the right ventricle (33.3%). In 100% of the cases, only one venous access was used for extraction of foreign bodies, and in 91.6% of the cases (11 catheters) the femoral access was used. The loop-snare was used in 10 cases (83.3%). The most common cause of intravascular foreign body insertion was a catheter fracture, which occurred in 66.6% of the cases (eight cases). One major complication, the atrial fibrillation, occurred (8.3%), which was related to the intravascular foreign body extraction. The mortality rate in 30 days was zero. CONCLUSION Percutaneous retrieval of intravascular foreign bodies is considered gold standard treatment because it is a minimally invasive, relatively simple, safe procedure, with low complication rates compared to conventional surgical treatment.
منابع مشابه
Percutaneous retrieval of lost or misplaced intravascular objects.
OBJECTIVE We report on our experience with percutaneous interventional techniques for retrieval of intravascular foreign bodies or repositioning of misplaced endovascular prostheses. MATERIALS AND METHODS Over a period of 6 years, we attempted percutaneous treatment of intravascular foreign bodies in 45 patients. The 45 foreign objects consisted of 12 endovascular stents, 14 catheter fragment...
متن کاملInterventional Removal of Intravascular Medical Devices: Methods and Technical Success Interventionelle Bergung intravasaler Fremdkörper: Methoden und technischer Erfolg
Correspondence Dr. Isabelle Ayx Radiologie, Barmherzige Brüder Regensburg Prüfeningerstraße 86 93049 Regensburg Germany Tel.: ++ 49/9 41/369943 72 Fax: ++ 49/9 41/3 692523 [email protected] Abstract ▼ Purpose: Evaluation of the technical success rate and complications when retrieving dislocated intravascular foreign bodies. Material and Methods: Between 1999 and 2015 38 patients (21 female; 17 m...
متن کاملIntravascular Foreign Bodies: A Single-Institution Experience and Description of a Novel Modified Percutaneous Retrieval Technique
To the Editor: Catheters are frequently used as diagnostic and therapeutic devices that are frequently placed in critically ill patients. In addition, with the advantage of radiologic technology, the number of minimally invasive endovascular procedures has increased, and consequently the reports of intravascular foreign bodies (IFBs)[1,2] and the numerous described IFBs retrieval technique.[3] ...
متن کاملPercutaneous endovascular retrieval of an intravascular foreign body in five dogs, a goat, and a horse.
CASE DESCRIPTION-5 Dogs, 1 goat, and 1 horse underwent percutaneous endovascular retrieval of intravascular foreign bodies between 2002 and 2007. CLINICAL FINDINGS-Foreign bodies were IV catheters in 4 dogs, the horse, and the goat and a piece of a balloon valvuloplasty catheter in 1 dog. Location of the foreign bodies included the main pulmonary artery (1 dog), a branch of a pulmonary artery (...
متن کاملVentricular Tract Hemorrhage Following Intracranial Nail Removal: Utility of Real-time Endovascular Assistance
Penetrating brain trauma commonly results in occult neurovascular injury. Detailed cerebrovascular imaging can evaluate the relationship of intracranial foreign bodies to major vascular structures, assess for traumatic pseudoaneurysms, and ensure hemostasis during surgical removal. We report a case of a self-inflicted intracranial nail gun injury causing a communicating ventricular tract hemorr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular
دوره 25 2 شماره
صفحات -
تاریخ انتشار 2010