Reproducibility of 24 h energy expenditure measurements using a human whole body indirect calorimeter.
نویسندگان
چکیده
Ten female subjects completed two similar experimental procedures (periods 1 and 2) to obtain values of reproducibility of energy intake and 24 h energy expenditure (24hEE) measurements in a whole body indirect calorimeter. The periods consisted of consumption of a provided weight-maintenance diet for 6-8 d, faeces and urine collection during the last 4 d and occupation of the calorimeter during the last 3 d. The daily routine inside the calorimeter simulated a sedentary day in normal life with some physical activity: 8 h sleep, 75 min bicycling and the remaining time spent on sedentary activities. The metabolizable energy (ME) content of the diet (14% energy as protein, 46% energy as carbohydrate, 40% energy as fat) was calculated using food tables. The actual ME intake as well as digestibility and metabolizability of the diet were obtained later by analyses of food, faeces and urine for energy. Three consecutive 24hEE measurements were performed during the stay in the calorimeter in each period. The time interval between the two periods varied from 2 to 24 months. Reproducibility was assessed at group and individual level. Mean digestibility and metabolizability of the diet showed no significant difference between periods. The within-subject coefficient of variation of metabolizability between periods was 1.7%. Mean 24hEE (MJ) over 3 d did not differ between period 1 (8.78 (SD 0.63)) and period 2 (8.73 (SD 0.66)). The within-subject coefficient of variation in mean 24hEE over three successive days between periods was 3.1% but decreased, after deletion of values for subjects who were less adapted to the calorimeter, to 1.9%.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Synchronous direct gradient layer and indirect room calorimetry.
A dual direct/indirect room-sized calorimeter is used at the Beltsville Human Nutrition Research Center to measure heat emission and energy expenditure in humans. Because the response times of a gradient layer direct calorimeter and an indirect calorimeter are not equivalent, the respective rate of heat emission and energy expenditure cannot be directly compared. A system of equations has been ...
متن کاملData Quality Control and Improvement of Indirect Human Calorimeter by System Dynamics Approach J. Futami &H. Kashiwazaki Data Quality Control and Improvement of Indirect Human Calorimeter by System Dynamics Approach
Using a system dynamics approach, a simulation model for data quality control and improvement of human calorimeter using the indirect calorimetry (IHC: indirect human calorimeter) was constructed. Accurate measurements of human energy expenditure are necessary in estimating appropriate energy requirement. IHC can measure continuously energy expenditure over 24 hours. O2 and CO2 analyzers and fl...
متن کاملAssessment of the heart-rate method for determining energy expenditure in man, using a whole-body calorimeter.
1. The heart-rate (HR) method for determining the energy expenditure of free-living subjects has been evaluated using a whole-body calorimeter in which individuals lived continuously for 27 h while carrying out normal daily activities. Eight male volunteers each occupied the calorimeter on at least two occasions when HR and energy expenditure were measured continuously. 2. After each session in...
متن کاملIntra-individual variability and measurement noise in estimates of energy expenditure by whole body indirect calorimetry.
1. Four men were each studied continuously over 12 d in a whole-body calorimeter. Dietary intake and daily activities were kept constant throughout the study. 2. Day-to-day coefficients of variation in energy expenditure within subjects were found to be 1.97% over 24 h, 5.93% during basal metabolic rate measurement, 2.40% overnight and 3.22% in exercise. 3. The contribution of measurement syste...
متن کاملEnergy expenditure and substrate metabolism measured by 24 h whole-body calorimetry in patients receiving cyclic and continuous total parenteral nutrition.
1. Twenty-four hour energy expenditure and its components, i.e. 'basal metabolic rate', activity energy expenditure and diet-induced thermogenesis were measured, using continuous whole-body indirect calorimetry, in patients receiving total parenteral nutrition while in remission from Crohn's disease (weight 51.9 +/- 9.9 kg, body mass index 19.2 +/- 2.0 kg/m2). 2. Total parenteral nutrition was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of nutrition
دوره 57 2 شماره
صفحات -
تاریخ انتشار 1987