Quantitation of countercurrent exchange during passive absorption from the dog small intestine: evidence for marked species differences in the efficiency of exchange.
نویسندگان
چکیده
The present investigation was designed to quantitatively assess the possible influence of countercurrent exchange on passive absorption from the small intestine of the dog. Villus blood flow was measured with a modification of the microsphere method. Simultaneously, the absorption from the gut lumen of five diffusible gases (H2, He, CH4, 133Xe, and CO) was determined. Villus blood flow averaged 0.247 +/- 0.03 (SEM) ml/min per g. The observed absorption of H2, He, CH4, and 133Xe was only 16.2 +/- 1.8, 12.8 +/- 2.3, 12.0 +/- 1.8, and 15.8 +/- 1.4 %, respectively, of what this villus blood flow could carry away if it reached perfect equilibrium with the luminal gases. This low absorption rate could result from diffusion limitation to absorption or countercurrent exchange. The diffusive permeability of the barrier seperating the luminal gases and villus blood flow was assessed by measuring the absorption rate of CO. Because absorbed CO binds tightly to hemoglobin, it cannot exchange, and when present in low concentrations its uptake is entirely diffusion limited. Knowledge of the diffusion rate through tissue of the unbound gases relative to that of CO made it possible to calculate the degree to which each of the unbound gases should equilibrate with villus tip blood. The percentage equilibration between lumen and blood at the villus tip for H2, He, CH4, and 133Xe was 99.7, 99.9, 75.6, and 36.0% , respectively. Each of these values greatly exceeded the percentage equilibration of blood leaving the villus (calculated from the observed absorption rate and villus blood flow) and indicated an exchange of 83.8, 87.2, 84.1, and 56.1% of initially absorbed H2, He, CH4, and 133Xe. This result is in accord with theoretical calculations which suggest that countercurrent exchange should be exceedingly efficient in the dog. The striking effect of countercurrent exchange on passive absorption in the dog differs from our previous studies in the rabbit where no exchange was demonstrated. This marked species difference may result from anatomical differences in villus architecture. The dog has long, densely packed villi while the rabbit has broad, widely spaced villi. In the dog, only the villus tips may equilibrate with the lumen, hence a countercurrent gradient may be established in the villus. The entire villus of the rabbit may equilibrate with the lumen and no gradient for countercurrent exchange can therefore be established.
منابع مشابه
A methodological approach for production and purification of polyclonal antibody against dog IgG
Antibodies are a class of biomolecules that has an important role in the immune system and lots of applications in biotechnological methods and in pharmaceutics. Production and purification of antibodies in laboratory animals is one of the first ways to manufacture of these prominent tools. The obtained antibodies from these process could be used in various types of bioassay techniques such as ...
متن کاملAn optimal semi-active thermal exchange-Fuzzy logic Controller for Structural Dynamic Control and Rehabilation
The effect of intelligent semi-active thermal exchange-fuzzy controller in structural rehabilitation by attenuating seismic responses of structural systems is investigated. In the suggested control system, MR dampers and sensors are employed as a semi-active controller. Resultant control forces of MR damper are administrated by providing external voltage supply, during the earthquakes and high ...
متن کاملThe Exchange Rate Misalignment, Volatility and the Export Performance: Evidence from Indonesia
T his study investigates the short-run and long-run impact of real exchange rate misalignment and volatility on Indonesian export to the US by exploiting the disaggregated data of export volume. The proxy of real exchange rate misalignment was obtained by estimating the fundamental equilibrium exchange rate (FEER) model, and the exchange rate volatility measured by employing the GARC...
متن کاملRemoval of heavy metals (lead, cadmium, zinc, nickel and iron) from water by bio-ceramic absorbers of hydroxy-apatite microparticles
Heavy metals are highly poisonous in the environment, even in small quantities, and endanger certain species and all live beings. Current methods of removing heavy metals from aqueous media include chemical sequestration, ion exchange, surface absorption, membrane processes, oxidation and revival procedures which have high investment and exploitation costs. Hence, it is significantly necessary ...
متن کاملCO2 Removal from Air in a Countercurrent Rotating Packed Bed, Experimental Determination of Height of Transfer Unit
Carbon dioxide capture is a key issue in climate change mitigation. For decades the removal of carbon dioxide has been an essential step in many industrial processing operations such as the synthesis of ammonia, natural gas purification, and oil refining. In this study, a rotating packed bed has been designed for absorption of carbon dioxide from an air stream. The rotating packed bed is a comp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of clinical investigation
دوره 59 2 شماره
صفحات -
تاریخ انتشار 1977