A New Complication of Swan-Ganz Catheterization
نویسنده
چکیده
CHEST, 75: 4, APRIL, 1979 PULMONARY ARTERY-BRONCHIAL FISTULA 515 signs in endocarditis following prosthetic valve replacement. J Thorac Cardiovasc Surg 58:554-557, 1968 3 Sutton CC, Wright JEC: Major detachment of aortic prosthetic valves. Br Heart J 32:337-343, 1970 4 Chandraratna PAN, Lopez JM, Hildner FJ, et al: Diagnosis of Bjork-Shiley aorticvalve dysfunction by echocardiography. Am Heart J 91:318-324, 1978 5 Srivastava TN, Hussain M, Gray LA, et al: Echocardiographic diagnosis of a stuck Bjork-Shiley aortic valve prosthesis.Chest 70:94-98, 1976 6 Orzan F, Garcia E, Pechacek LW, et al: Ultrasonic evaluation of thrombosis of Bjork-Shiley aortic valve prosthesis.J Thorac Cardiovasc Surg 74:11-13, 1977 7 Feigenbaum H: Echocardiography, 2nd ed. Philadelphia, Lea & Febiger, 1976, p 209 8 Johnson ML: Echocardiographic evaluation of prosthetic heart valves. In Gramiak R, Waag RC (eds): Cardiac Ultrasound. St. Louis, CV Mosby, 1975 9 Winters WL Jr. Gimenez J, Soloff LA: Clinical application of ultrasound in the analysis of prosthetic ball valve function. Am J Cardiol 19:97-107, 1967 10 Roelandt J, van Dorp WG, Bom N, et al: Resolution problems in echocardiology: A source of interpretation errors. Am J Cardiol 37:258-262, 1976
منابع مشابه
Pulmonary artery rupture as a complication of Swan-Ganz catheter application. Diagnosis and endovascular treatment: a single centre's experience
INTRODUCTION The placement of a Swan-Ganz catheter into the pulmonary artery may lead to a number of complications (2-17%). In less than 0.2% of cases Swan-Ganz catheterization results in serious vascular damage - pulmonary artery rupture (PAR). This paper presents two distinct forms of iatrogenic PAR treated endovascularly using different vascular devices. AIM To evaluate the effectiveness o...
متن کاملRuptured chordae of the tricuspid valve. The consequence of flow-directed Swan-Ganz catheterization.
A case of autopsy-documented ruptured chordae tendineae of the tricuspid valve, secondary to flow-directed Swan-Ganz catheterization of the right side of the heart is presented. A possible mechanism is discussed and safeguards to prevent this complication are suggested.
متن کاملEndovascular treatment of PA pseudoaneurysm caused by Swan-Ganz catheter
The following case report describes a complication of Swan-Ganz catheterization and its endovascular treatment with a single coil. Application of this particular catheter in the pulmonary artery during cardiac surgery may lead to mechanical perforation and creation of an extravascular sac, which is called a pseudoaneurysm. There are different methods that lead to tamponade or closure of the lea...
متن کاملPulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report
Pulmonary artery (PA) rupture caused by a PA Swan-Ganz catheter is a rare complication but remains fatal in almost 50% of cases. False aneurysm of the PA is a rare presentation of PA rupture and should be considered as a possible diagnosis in a patient with a new lung mass after PA catheterization. We present a case of sudden-onset pulmonary alveolar hemorrhage during cardiovascular surgery due...
متن کاملVertebral arteriovenous fistula: an unusual complication of Swan-Ganz catheter insertion.
The leading causes of trauma to the major craniocerebral vessels include penetrating and non penetrating trauma [1 , 2]. Because the vertebral artery is confined to the incomplete bony canal formed by the successive foramina in the transverse processes of the upper cervical vertebrae, it is less susceptible to penetrating injury than is the carotid artery [2]. A review of the literature has unc...
متن کاملSwan-Ganz catheter-induced pulmonary artery pseudoaneurysm formation: three case reports and a review of the literature.
The use of Swan-Ganz catheters has increased tremendously since they were first introduced in 1970. Their ability to give vital hemodynamic measurements in critically ill patients makes their use invaluable when providing quality medical care. The formation of pulmonary artery (PA) pseudoaneurysm from a Swan-Ganz catheter-induced perforation of the PA is a rare but potentially fatal complicatio...
متن کامل