Sutureless securement device reduces complications of peripherally inserted central venous catheters.
نویسندگان
چکیده
PURPOSE This study was conducted to evaluate the performance of a sutureless adhesive-backed device, StatLock, for securement of peripherally inserted central venous catheters (PICCs). Earlier studies have demonstrated that StatLock significantly reduces catheter-related complications when compared to tape. The purpose of this study was to determine whether a sutureless securement device offers an advantage over suture in preventing catheter-related complications. MATERIALS AND METHODS 170 patients requiring PICCs, which were randomized to suture (n = 85) or StatLock (n = 85) securement were prospectively studied. Patients were followed throughout their entire catheter course, and PICC-related complications including dislodgment, infection, occlusion, leakage, and central venous thrombosis were documented. Catheter outcome data were compared to determine if statistically significant differences existed between the suture and StatLock groups. RESULTS The groups had equivalent demographic characteristics and catheter indications. Average securement time with StatLock was significantly shorter (4.7 minutes vs 2.7 minutes;P <.001). Although StatLock was associated with fewer total complications (42 vs 61), this difference did not achieve significance. However, there were significantly fewer PICC-related bloodstream infections in the StatLock group (2 vs 10; P =.032). One securement-related needle-stick injury was documented during suturing of a PICC. CONCLUSION The sutureless anchor pad was beneficial for both patients and health care providers. Further investigation to determine how StatLock helps reduce catheter-related blood stream infections is necessary.
منابع مشابه
Catheter Securement Systems for Peripherally Inserted and Nontunneled Central Vascular Access Devices
Sutureless catheter securement systems are intended to eliminate risks associated with sutures. The clinical acceptability of a novel system was investigated compared with the current method of securement for peripherally inserted central catheters (19 facilities using StatLock or sutures) or nontunneled central vascular access devices (3 facilities using StatLock or sutures or HubGuard + Sorba...
متن کاملCentral venous Access device SeCurement And Dressing Effectiveness (CASCADE) in paediatrics: protocol for pilot randomised controlled trials
INTRODUCTION Paediatric central venous access devices (CVADs) are associated with a 25% incidence of failure. Securement and dressing are strategies used to reduce failure and complication; however, innovative technologies have not been evaluated for their effectiveness across device types. The primary aim of this research is to evaluate the feasibility of launching a full-scale randomised cont...
متن کاملCentral venous Access device SeCurement And Dressing Effectiveness for peripherally inserted central catheters in adult acute hospital patients (CASCADE): a pilot randomised controlled trial
BACKGROUND Peripherally inserted central catheters (PICCs) are commonly used for delivering intravenous therapy. PICC failure is unacceptably high (up to 40%) due to mechanical, infectious and thrombotic complications. Poor securement potentiates all complication types. This randomised controlled trial (RCT) aimed to examine the feasibility of a large RCT of four dressing and securement methods...
متن کاملComplications of Peripheral Venous Access Devices: Prevention, Detection, and Recovery Strategies.
Most hospitalized patients have placement of a peripheral venous access device, either a short peripheral catheter or a peripherally inserted central catheter. Compared with central venous catheters that are not peripherally inserted, the other 2 types are generally perceived by health care providers as safer and less complicated to manage, and less emphasis is placed on the prevention and mana...
متن کاملA prospective trial on a new sutureless securement device for central venous catheters.
To the Editor, We share our experience with a new catheter securement device called the SecurAcath" (Interrad Medical, Plymouth, MN, USA). It utilizes small folding subcutaneous nitinol tines that anchor an intravenous catheter at the insertion site (Figure, panels A and B). The anchor is designed to be atraumatic, and it is magnetic resonance imaging compatible. An instructional video provided...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of vascular and interventional radiology : JVIR
دوره 13 8 شماره
صفحات -
تاریخ انتشار 2002