A depth-of-interaction PET detector using a stair-shaped reflector arrangement and a single-ended scintillation light readout.

نویسندگان

  • Jeong-Whan Son
  • Min Sun Lee
  • Jae Sung Lee
چکیده

Positron emission tomography (PET) detectors with the ability to encode depth-of-interaction (DOI) information allow us to simultaneously improve the spatial resolution and sensitivity of PET scanners. In this study, we propose a DOI PET detector based on a stair-pattern reflector arrangement inserted between pixelated crystals and a single-ended scintillation light readout. The main advantage of the proposed method is its simplicity; DOI information is decoded from a flood map and the data can be simply acquired by using a single-ended readout system. Another potential advantage is that the two-step DOI detectors can provide the largest peak position distance in a flood map because two-dimensional peak positions can be evenly distributed. We conducted a Monte Carlo simulation and obtained flood maps. Then, we conducted experimental studies using two-step DOI arrays of 5  ×  5 Lu1.9Y0.1SiO5:Ce crystals with a cross-section of 1.7  ×  1.7 mm2 and different detector configurations: an unpolished single-layer (US) array, a polished single-layer (PS) array and a polished stacked two-layer (PT) array. For each detector configuration, both air gaps and room-temperature vulcanization (RTV) silicone gaps were tested. Detectors US and PT showed good peak separation in each scintillator with an average peak-to-valley ratio (PVR) and distance-to-width ratio (DWR) of 2.09 and 1.53, respectively. Detector PSRTV showed lower PVR and DWR (1.65 and 1.34, respectively). The configuration of detector PTAir is preferable for the construction of time-of-flight-DOI detectors because timing resolution was degraded by only about 40 ps compared with that of a non-DOI detector. The performance of detectors USAir and PSRTV was lower than that of a non-DOI detector, and thus these designs are favorable when the manufacturing cost is more important than timing performance. The results demonstrate that the proposed DOI-encoding method is a promising candidate for PET scanners that require high resolution and sensitivity and operate with conventional acquisition systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel method to calibrate DOI function of a PET detector with a dual-ended-scintillator readout.

The detection of depth-of-interaction (DOI) is a critical detector capability to improve the PET spatial resolution uniformity across the field-of-view and will significantly enhance, in particular, small bore system performance for brain, breast, and small animal imaging. One promising technique of DOI detection is to use dual-ended-scintillator readout that uses two photon sensors to detect s...

متن کامل

A dual-ended readout PET detector module based on GAPDs with large-area microcells

The use of a dual-ended readout PET detector module based on Geiger-mode avalanche photodiodes (GAPDs) with large-area microcells was proposed to obtain high photon detection efficiency (PDE) and overcome energy non-linearity problems. A simulation study was performed and experimental measurement were taken for the singleand dual-ended PET detector modules consisting of the two types of GAPDs w...

متن کامل

A New Photodiode Readout Scheme for High Resolution Scintillation Crystal Arrays

We are exploring the possibility of using PIN photodiodes to readout the scintillation crystals used in Positron Emission Tomography (PET) detector designs. Solid state photodetectors typically have a lower signal to noise ratio than photomultiplier tubes (PMTs). However, they have the advantage of compactness, and, thus, scintillation crystal readout schemes not available to PMTs because of th...

متن کامل

Investigation of a New Readout Scheme for High Resolution Scintillation Crystal Arrays Using Photodi - Nuclear Science, IEEE Transactions on

We are exploring the possibility of using PIN photodiodes to readout the scintillation crystals used in Positron Emission Tomography (PET) detector designs. Semiconductor photodetectors typically have a lower signal to noise ratio than photomultiplier tubes (PMTs). However, they have the advantage of compactness, and, thus, scintillation crystal readout schemes not available to PMTs because of ...

متن کامل

Monte Carlo calculations of PET coincidence timing: single and double-ended readout

We present Monte Carlo computational methods for estimating the coincidence resolving time (CRT) of scintillator detector pairs in positron emission tomography (PET) and present results for Lu2SiO5 : Ce (LSO), LaBr3 : Ce, and a hypothetical ultra-fast scintillator with a 1 ns decay time. The calculations were applied to both single-ended and double-ended photodetector readout with constant-frac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 62 2  شماره 

صفحات  -

تاریخ انتشار 2017