Comparison of image quality and acquistion time of Free-Breathing (FB) motion corrected (MOCO) SSFP to current PSIR sequences: is one sequence superior?

نویسندگان

  • Ryan Avery
  • Rajesh Janardhanan
  • Clinton Jokerst
چکیده

Background Delayed myocardial enhancement (DE) sequences have become essential in cardiac MRI (CMRI) for visualization of abnormal myocardium. DE sequences require an inversion pulse to null normal myocardium, and the introduction of phase-sensitive inversion recovery (PSIR) sequences, which are less sensitive to small variations in inversion time (TI), have provided a suitable alternative to magnitude inversion recovery sequences. Two PSIR sequences are widely available, the single-shot SSFP PSIR (SS-SSFP) and segmented turbo FLASH (STF) PSIR sequences. The SS-SSFP PSIR sequence has a short acquisition time making it motion insensitive, but also limiting resolution. The STF PSIR is a longer sequence with better resolution, but also requires several breath holds. The recent introduction of a free-breathing (FB) motion-corrected (MOCO) version of the SS-SSFP PSIR (FB MOCO SSFP) may offer a compromise between image resolution and acquisition time by combining the speed and motion-insensitivity of SS-SSFP PSIR with a resolution similar to STF PSIR. Since CMRI is a timeintensive exam, comparison of these sequences regarding both image quality and acquisition time is necessary.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The validity of a free breathing motion corrected phase sensitive inversion recovery sequence in the detection of delayed myocardial enhancement in non-ischemic heart disease

Background Breath-hold (BH) segmented TURBO FLASH (TFL) is currently used as the gold standard technique to evaluate delayed enhancement (DE) of the myocardium, typically with a phase sensitive inversion recovery (PSIR) approach (1). However, many patients are unable to perform adequate breath-holding resulting in poor image quality and limited diagnostic yield. Free breathing (FB) single shot ...

متن کامل

Comparison of a novel free breathing SSFP sequence with standard breath held SSFP- a pilot study

Background Despite advances in magnetic resonance imaging hardware and software, the acquisition of optimal cardiac magnetic resonance (CMR) images may be hampered by several factors. Most notably, scan length, the requirement for multiple breath holds and cardiac gating can all impact upon image quality. Real time cardiac imaging holds promise for reducing scan times via rapid acquisitions of ...

متن کامل

Single center experience with a prototype self-navigated 3D SSFP whole heart sequence in assessing coronary artery origin

Background This prototype, self navigated, free breathing 3D sequence acquires continuous ECG-segmented radial views of the heart with 100% scan efficiency, without a beam-navigator, and without the time expense of scanning within a range of diaphragmatic positions. The reconstructed image is respiratory motion corrected based on the inferior-superior motion of the left ventricular blood pool. ...

متن کامل

Motion-corrected free-breathing delayed enhancement imaging of myocardial infarction.

Following administration of Gd-DTPA, infarcted myocardium exhibits delayed enhancement and can be imaged using an inversion-recovery sequence. A conventional segmented acquisition requires a number of breath-holds to image the heart. Single-shot phase-sensitive inversion-recovery (PSIR) true-FISP may be combined with parallel imaging using SENSE to achieve high spatial resolution. SNR may be im...

متن کامل

Free-breathing, motion-corrected late gadolinium enhancement is robust and extends risk stratification to vulnerable patients.

BACKGROUND Routine clinical use of novel free-breathing, motion-corrected, averaged late-gadolinium-enhancement (moco-LGE) cardiovascular MR may have advantages over conventional breath-held LGE (bh-LGE), especially in vulnerable patients. METHODS AND RESULTS In 390 consecutive patients, we collected bh-LGE and moco-LGE with identical image matrix parameters. In 41 patients, bh-LGE was abando...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015