Oxygen cylinders are heavy and present a number of hazards, and liquid oxygen is too heavy and cumbersome to be used in far forward environments. Portable oxygen concentrators (POCs) and chemical oxygen generators (COGs) have been proposed as a solution. We evaluated 3 commercially available POCs and 3 COGs in a laboratory setting. Altitude testing was done at sea level and 8,000, 16,000, and 22,000 ft. Temperature extreme testing was performed after storing devices at 60°C and -35°C for 24 hours. Mean FIO2 decreased after storage at -35°C with Eclipse and iGo POCs and also at the higher volumes after storage at 60°C with the Eclipse. The iGo ceased to operate at 16,000 ft, but the Eclipse and Saros were unaffected by altitude. Oxygen flow, duration of operation, and total oxygen volume varied between COGs and within the same device type. Output decreased after storage at -35°C, but increased at each altitude as compared to sea level. This study showed significant differences in the performance of POCs and COGs after storage at temperature extremes and with the COGs at altitude. Clinicians must understand the performance characteristics of devices in all potential environments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Operating condition effect on achieving higher propene yield in propane oxidative dehydrogenation process

Supported vanadia catalyst was successfully synthesized using wet impregnation of gamma-Alumina to study Propane Oxidative Dehydrogenation (POD). The prepared catalysts were characterized with XRD, BET, and TPR tests. In a broad temperature range (340 to 630°C), effects of vanadia loading (2.7, 5.4, and 9 wt%) and propane to oxygen ratio (3/1 to 1/3) were investigated on propane conversion as w...

متن کامل

Operating condition effect on achieving higher propene yield in propane oxidative dehydrogenation process

Supported vanadia catalyst was successfully synthesized using wet impregnation of gamma-Alumina to study Propane Oxidative Dehydrogenation (POD). The prepared catalysts were characterized with XRD, BET, and TPR tests. In a broad temperature range (340 to 630°C), effects of vanadia loading (2.7, 5.4, and 9 wt%) and propane to oxygen ratio (3/1 to 1/3) were investigated on propane conversion as w...

متن کامل

A Numerical Simulation of Inspiratory Airflow in Human Airways during Exercise at Sea Level and at High Altitude

At high altitudes, the air pressure is much lower than it is at sea level and contains fewer oxygen molecules and less oxygen is taken in at each breath. This requires deeper and rapid breathing to get the same amount of oxygen into the blood stream compared to breathing in air at sea level. Exercises increase the oxygen demand and make breathing more difficult at high altitude. In this study, ...

متن کامل

CFD Modeling Study of High Temperature and Low Oxygen Content Exhaust Gases Combustion Furnaces

This paper reports a CFD modeling study on the possibility of using high temperature and low oxygen content exhaust gases as oxidant for combustion in an industrial furnace by a written computer program. Under these conditions,the predicted results for the flow and heat transfer properties are compared with those under the several cases of conventional and highly preheated...

متن کامل

Evaluation of sequencing batch reactor performance for petrochemical wastewater treatment

Sequencing batch reactor (SBR) technology has found many applications in industrial wastewater treatment in recent years. The aim of this study was to determine the optimal time for a cycle of the sequencing batch reactor (SBR) and evaluate the performance of a SBR for petrochemical wastewater treatment in that cycle time. The reactor was operated with a suspended biomass configuration under ae...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Military medicine

دوره 181 5 Suppl  شماره 

صفحات  -

تاریخ انتشار 2016