In this paper, we propose a theoretical model to simulate microbial growth on contaminated air filters and entrainment of bioaerosols from the filters to an indoor environment. Air filter filtration and antimicrobial efficiencies, and effects of dust particles on these efficiencies, were evaluated. The number of bioaerosols downstream of the filter could be characterized according to three phases: initial, transitional, and stationary. In the initial phase, the number was determined by filtration efficiency, the concentration of dust particles entering the filter, and the flow rate. During the transitional phase, the number of bioaerosols gradually increased up to the stationary phase, at which point no further increase was observed. The antimicrobial efficiency and flow rate were the dominant parameters affecting the number of bioaerosols downstream of the filter in the transitional and stationary phase, respectively. It was found that the nutrient fraction of dust particles entering the filter caused a significant change in the number of bioaerosols in both the transitional and stationary phases. The proposed model would be a solution for predicting the air filter life cycle in terms of microbiological activity by simulating the microbial contamination of the filter.
منابع مشابه
A Risk for Nosocomial Infections: Contamination of Hospital Air Cooling Systems by Acantamoeba spp.
Background and Objectives: In the most Iranian hospitals the internal air is cooled by a system comprising centrifugal blower fan and excelsior filters. Because amoeba can be present in air and dust it may enter into filters of cooling systems. It has been suggested that diffusion of amoebae cyst through air canals may contribute to various types of nosocomial infections. This ...
متن کاملMicrobial Profile of Air Contamination in Hospital Wards
Background and Aims:Nosocomial infections cause considerable morbidity and mortality and pose high financial burden on healthcare systems. Although surface contact, surgical incisions, wounds and catheters are responsible for a high percentage of nosocomial infections, bacterial and fungal air contaminations in hospitals have an important role in development of hospital infections. The p...
متن کاملEvaluation of the Effects of Different Filters and Helium Bag on the Reduction of Electron Contamination in Photon Beam of Neptun Linac
Introduction: Skin sparing is one of the most desirable characteristics of high energy photon beams. However, the photons emerging from the target of linacs are contaminated by secondary electrons as a result of their interactions with air, collimators, flattening filter and any other objects in their path. This phenomenon tends to increase the skin dose received b...
متن کاملClean Air Solutions in Food Processing
This literature review deals with air handling in controlled environments in the food industry. The concern to determine the importance of the airflow as a possible source of contamination is growing, because the airborne dust particles can introduce foreign matter including microbial contaminants into the products produced. The following criteria should be used to determine a sampling strategy...
متن کاملForced-air warming blowers: An evaluation of filtration adequacy and airborne contamination emissions in the operating room.
BACKGROUND Forced-air warming (FAW) is widely used to prevent hypothermia during surgical procedures. The airflow from these blowers is often vented near the operative site and should be free of contaminants to minimize the risk of surgical site infection. Popular FAW blowers contain a 0.2-μm rated intake filter to reduce these risks. However, there is little evidence that the efficiency of the...
متن کامل