Implementation of sine condition test to measure optical system misalignments.
نویسندگان
چکیده
Rather than measuring aberrations across the field to quantify the alignment of an optical system, we show how a single, on-axis measurement of the pupil mapping can be used to measure the off-axis performance of the system and determine the state of alignment. In this paper we show how the Abbe sine condition can be used to relate the mapping between the entrance and exit pupils to image aberrations that have linear field dependence. This mapping error then can be used to measure the linear astigmatism caused by the misalignment. Additionally, we present experimental results from the sine condition test on a simple system.
منابع مشابه
An Optical Measurement System to Measure Velocity and Provide Shock Wave Pressure Diagrams
This paper introduces an optical measurement system for shock wave characteristics. The system works by mountinga metal plate attached to spring mounts against the shock wavefront. This set is sealed and can plot the shock wave pressure diagram by measuring plate's displacement, radiation and changing the reflection of light during shock wave conflict, and converting these optical data to volta...
متن کاملDesigning and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals
Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...
متن کاملTwo-mirror telescope design with third-order coma insensitive to decenter misalignment.
Misalignments always occur in real optical systems. These misalignments do not generate new aberration forms, but they change the aberration field dependence. Two-mirror telescopes have been used in several applications. We analyze a two-mirror telescope configuration that has negligible sensitivity to decenter misalignments. By applying the wave aberration theory for plane-symmetric optical sy...
متن کاملMisalignments in ERP Implementation: A Dialectic Perspective
Enterprise resource planning (ERP) systems are often not fully aligned with the implementing organization. It is important to understand their sources of misalignments because they can have significant implications for the organization. From a dialectic perspective, such misalignments are the result of opposing forces that arise from structures embedded in the ERP package and the organization. ...
متن کاملBridging the ‘Two Cultures’ of Research and Service: Can Complexity Theory Help?; Comment on “Experience of Health Leadership in Partnering With University-Based Researchers in Canada – A Call to ‘Re-imagine’ Research”
This commentary addresses Bowen et al’s empirical study of perspectives of Canadian healthcare staff towards research and their call for multi-faceted action to improve misalignments in the system. This commentary argues that tensions and misalignments between research and service are inherent and can never be eradicated. Building on previous work by Lanham et al, I pro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 50 34 شماره
صفحات -
تاریخ انتشار 2011