Interference fringe scale for absolute ocular fundus measurement.
نویسندگان
چکیده
Measurements of the human ocular fundus in the three spatial dimensions have not been absolute because measuring techniques have used the optical system of the eye as part of the total ophthalmoscopic system. The ophthalmoscopic magnification due to the total dioptric power of an individual eye can vary substantially from that of the average eye. A new method has been developed to form interference fringes on the fundus so that the fringe spacing can be calculated within a small error by using measured values. The photographed fringes then act as a scale at the fundus with the fringe spacings serving as the graduations, thus allowing accurate absolute measurements of the fundus through the interfering ocular media.
منابع مشابه
Absolute Measurement of Base Lines up to 400 M Using Temporal Coherence Heterodyne Interferometer of Optical Frequency Comb
A heterodyne interference system is developed for base-lines measurement by using an acoustic optical modulator and a stabilized optical-frequency comb. The temporal coherence interference with the optical-frequency comb happen at discrete positions, where a pair of pulse trains overlaps with each other. An optical delay of the interferometer with a piezo-electric transducer is realized to find...
متن کاملAbsolute phase measurement in fringe projection using multiple perspectives.
A technique for absolute phase measurement in fringe projection for shape measurement is presented. A standard fringe projection system is used, comprising a camera and a projector fixed relative to each other. The test object is moved to different orientations relative to the fringe projection system. Using the system calibration parameters, the technique identifies homologous surface areas im...
متن کاملAbsolute measurement of a long, arbitrary distance to less than an optical fringe.
A scheme is proposed for high-precision, absolute length measurement for an arbitrary optical distance of a few meters to beyond 10(6) m. The approach utilizes a phase-stabilized femtosecond laser to provide both incoherent, time-of-flight information and coherent, fringe-resolved interferometry. Such a combined measurement capability allows an optical wavelength resolution to be achieved for a...
متن کاملMicrostructure characterization of amorphous thin solid films in a fringe-free environment
We have comprehensively analyzed the influence of the probe beam’s polarization state and incident angle on the vibrational absorption spectra of thin solid films such as hydrogenated amorphous silicon nitride and hydrogenated amorphous silicon in Fourier transform infrared spectroscopy. This analysis demonstrates the nuisance of interference fringes in distorting the bond structure of thin sol...
متن کاملHigh-precision absolute distance measurement using dual-laser frequency scanned interferometry under realistic conditions
In this paper, we report on new high-precision absolute distance measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distances were determined by counting the interference fringes produced while scanning the frequencies of the two chopped lasers. High-finesse Fabry–Perot interferometers were used to determine frequency changes during...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 24 2 شماره
صفحات -
تاریخ انتشار 1983