On the selection of optimization parameters for an inverse treatment planning replacement of a forward planning technique for prostate cancer
نویسندگان
چکیده
The influence of organ volume sampling, lateral scatter inclusion, and the selection of objectives and constraints on the inverse treatment planning process with a commercial treatment planning system is investigated and suitable parameters are identified for an inverse treatment planning replacement of a clinical forward planning technique for prostate cancer. For the beam geometries of the forward technique, a variable set of parameters is used for the calculation of dose from pencil beams. An optimal set is identified after the evaluation of optimized plans that correspond to different sets of pencil-beam parameters. This set along with a single, optimized set of objectives and constraints is used to perform inverse planning on ten randomly selected patients. The acceptability of the resulting plans is verified by comparisons to the clinical ones calculated with the forward techniques. For the particular commercial treatment planning system, the default values of the pencil beam parameters are found adequate for inverse treatment planning. For all ten patients, the optimized, single set of objectives and constraints results in plans with target coverage comparable to that of the forward plans. Furthermore inverse treatment planning reduces the overall mean rectal and bladder doses by 4.8% and 5.8% of the prescription dose respectively. The study indicates that (i) inverse treatment planning results depend implicitly on the sampling of the dose distribution, (ii) inverse treatment planning results depend on the method used by the dose calculation model to account for scatter, and (iii) for certain sites, a single set of optimization parameters can be used for all patient plans.
منابع مشابه
Comparison between field-in-field technique and the use of conventional wedges for treatment planning of esophageal cancer
Introduction: This study was conducted to evaluate and quantify the treatment planning performance of MLC-optimized field-in-field planning technique (FIF), also named forward IMRT, versus wedge-based three field (W3F) technique in terms of dosimetric and radiobiological parameters for esophageal carcinoma. Material and Methods: Twenty patients with esophag...
متن کاملIterative Approach for Automatic Beam Angle Selection in Intensity Modulated Radiation Therapy Planning
Introduction: Beam-angle optimization (BAO) is a computationally intensive problem for a number of reasons. First, the search space of the solutions is huge, requiring enumeration of all possible beam orientation combinations. For example, when choosing 4 angles out of 36 candidate beam angles, C36 = 58905 possible combinations exist. Second, any change in a beam 4 config...
متن کاملUsing PSO algorithm optimization for planning 103Pd seeds brachytherapy positions
Radiation therapy, is one of the treatments for cancer. Brachytherapy is a radiotherapeutic technique that a sealed radiation source is placed inside or next to the tissue and has become a mainstream treatment option for cancer. Achieving maximum dose to the gland as well as minimum injury to the adjacent tissues is a basic principle in radiation therapy. Sources configuration must be designed ...
متن کاملRadiation treatment planning for prostate cancer: A new dosimetric comparison of five and seven fields IMRT plans
Background: To compare the dosimetric coverage of the planning target volume (PTV) and the dose delivered to the main Organs at Risk (OARs) in 5 and 7-field techniques of Intensity Modulated Radiation Therapy (IMRT) in patients with local prostate cancer. Materials and Methods: Twelve patients with local prostate cancer underwent 5 and 7-field IMRT planning. The delivery of IMRT was carried out...
متن کاملEvaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques
Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...
متن کامل