Estimation of Organic Vapor Breakthrough in Humidified Activated Carbon Beds: -Application of Wheeler-Jonas Equation, NIOSH MultiVapor™ and RBT (Relative Breakthrough Time)
نویسندگان
چکیده
OBJECTIVES In the use of activated carbon beds as adsorbents for various types of organic vapor in respirator gas filters, water adsorption of the bed and test gas humidity are expected to alter the accuracy in the estimation of breakthrough data. There is increasing interest in the effects of moisture on estimation methods, and this study has investigated the effects with actual breakthrough data. METHODS We prepared several activated carbon beds preconditioned by equilibration with moisture at different relative humidities (RH=40%-70%) and a constant temperature of 20°C. Then, we measured breakthrough curves in the early region of breakthrough time for 10 types of organic vapor, and investigated the effects of moisture on estimation using the Wheeler-Jonas equation, the simulation software NIOSH MultiVapor™ 2.2.3, and RBT (Relative Breakthrough Time) proposed by Tanaka et al. RESULTS The Wheeler-Jonas equation showed good accordance with breakthrough curves at all RH in this study. However, the correlation coefficient decreased gradually with increasing RH regardless of type of organic vapor. Estimation of breakthrough time by MultiVapor showed good accordance with experimental data at RH=50%. In contrast, it showed discordance at high RH (>50%). RBTs reported previously were consistent with experimental data at RH=50%. On the other hand, the values of RBT changed markedly with increasing RH. CONCLUSIONS The results of each estimation method showed good accordance with experimental data under comparatively dry conditions (RH≤50%). However, there were discrepancies under high humidified conditions, and further studies are warranted.
منابع مشابه
Reduction of Adsorption Capacity of Activated Carbon
In occupational hygiene, activated carbon produced from coconut shell is a common adsorbent material for harmful substances including organic vapors due to its outstanding adsorption capacity and cost advantage. However, moisture adsorption of the carbon generally decreases the adsorption capacity for organic vapors. In a previous report, we prepared several coconut shell activated carbons whic...
متن کاملUsing the Wheeler-jonas Equation to Describe Adsorption of Inorganic Molecules: Ammonia
Activated carbons can adsorb a wide variety of substances. This is the reason why they are used in canisters to guarantee the safety of the people. The use of the canisters is dependent on several parameters which makes it interesting if the safety margins of the filter can be predicted. The Wheeler-Jonas equation is a well-known predictive equation for describing organic vapour breakthrough ti...
متن کاملX-ray Microtomography: a Useful Method to Study the Dynamics of Organic and Water Vapours Adsorption on Carbon
The suitability of the X-ray microtomographic technique to study the dynamics of vapor adsorption on carbon beds was assessed in this work. This technique was tested using three different systems: CH3I, water vapor and a mixture of waterand organic vapors. Image analysis of the carbon bed cross-sections obtained by X-ray microtomography allows determining the adsorption front progress in the ca...
متن کاملModification of activated carbon by cold plasma and its effect on the adsorption of toluene
Abstract Background and aims: Clean air is one of the basic needs for human health and well-being. However, along with economic growth and development, transportation, urbanization and energy consumption have also risen and provide many concerns such as air pollution, which require urgent and wide attention. Air pollution in the worldwide is considered as a risk factor for human health and one...
متن کاملBreakthrough behavior of sulphur mustard vapor on activated carbon
Active carbon (surface area, 1250 m/g) was used to study vapor breakthrough behavior of sulphur mustard (2, 2’dichlorodiethyl sulphide). Effect of length of carbon bed on vapor breakthrough time has been examined. Rate constant (k v ) is found to increase while kinetic saturation capacity (W e ) is invariable with increase in airflow rate. Both k v and W e decrease with the increase of temperat...