Intraoperative somatosensory evoked potential monitoring during anterior cervical discectomy and fusion in nonmyelopathic patients--a review of 1,039 cases.
نویسندگان
چکیده
BACKGROUND CONTEXT Intraoperative somatosensory evoked potential (SSEP) monitoring has been shown to reduce the incidence of new postoperative neurological deficits in scoliosis surgery. However, its usefulness during cervical spine surgery remains a subject of debate. PURPOSE To determine the utility of intraoperative SSEP monitoring in a specific patient population (those with cervical radiculopathy in the absence of myelopathy) who underwent anterior cervical discectomy and fusion (ACDF) surgery. STUDY DESIGN Retrospective review. PATIENT SAMPLE A total of 1,039 nonmyelopathic patients who underwent single or multilevel ACDF surgery. The control group (462 patients) did not have intraoperative SSEP monitoring, whereas the monitored group (577 patients) had continuous intraoperative SSEP monitoring performed. OUTCOME MEASURE A new postoperative neurological deficit. METHODS SSEP tracings were reviewed for all 577 patients in the monitored group and all significant signal changes were noted. Medical records were reviewed for all 1,039 patients to determine if any new neurological deficits developed in the immediate postoperative period. RESULTS None of the patients in the control group had any new postoperative neurological deficits. In the monitored group there were six instances of transient SSEP changes (1 due to suspected carotid artery compression; 5 thought to be due to transient hypotension) which resolved with the appropriate intraoperative intervention (repositioning of retractors; raising the arterial blood pressure). Upon waking up from anesthesia, one patient in the monitored group had a new neurological deficit (partial central cord syndrome) despite normal intraoperative SSEP signals. CONCLUSIONS ACDF appears to be a safe surgical procedure with a low incidence of iatrogenic neurological injury. Transient SSEP signal changes, which improved with intraoperative interventions, were not associated with new postoperative neurological deficits. An intraoperative neurological deficit is possible despite normal SSEP signals.
منابع مشابه
Two cases of quadriparesis following anterior cervical discectomy, with normal perioperative somatosensory evoked potentials.
Two cases illustrate an uncommon failure of perioperative somatosensory evoked potential (SEP) monitoring to detect iatrogenic lesions causing temporary quadriparesis during straightforward cervical surgery. In both cases, anterior cervical discectomy at one or two levels was undertaken with bone graft and titanium implants, and cortical SEP were monitored to alternate stimulation of the left a...
متن کاملComparison of transcranial electric motor and somatosensory evoked potential monitoring during cervical spine surgery.
BACKGROUND There has been little enthusiasm for somatosensory evoked potential monitoring in cervical spine surgery as a result, in part, of the increased risk of motor tract injury at this level, to which somatosensory monitoring may be insensitive. Transcranial electric motor evoked potential monitoring allows assessment of the motor tracts; therefore, we compared transcranial electric motor ...
متن کاملComparison of outcomes and safety of using hydroxyapatite granules as a substitute for autograft in cervical cages for anterior cervical discectomy and interbody fusion
Background: After cervical discectomy, autogenetic bone is packed into the cage to increase the rate of union between adjacent vertebral bodies, but donor site–related complications can still occur. In this study we evaluate the use of hydroxyapatite granules as a substitute for autograft for interbody fusion. Methods: From November 2008 to November 2011, 236 patients participated in ...
متن کاملIntraoperative neurophysiological monitoring during spine surgery: an update
Purpose of review Intraoperative neurophysiological monitoring (IONM) during spine surgery has dramatically evolved over the past decade. A number of techniques have been recently proposed to monitor motor evoked potentials (MEPs), but contradictory results have been published, questioning their reliability to assess specifically the functional integrity of the motor pathways. The aim of the re...
متن کاملNeurophysiological monitoring of spinal cord function during instrumented anterior cervical fusion.
BACKGROUND CONTEXT Somatosensory evoked potentials (SSEPs) monitor global spinal cord function, and the interpretation of motor loss is based on inferred rather than direct measurements. Therefore, SSEPs may not be useful for identifying motor function deficits caused by anterior spinal column injury or nerve root injury during decompression or placement of instrumentation. For these reasons, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The spine journal : official journal of the North American Spine Society
دوره 7 1 شماره
صفحات -
تاریخ انتشار 2007