Miscalibration and severe complications after diode laser cyclophotocoagulation: two case reports.

نویسندگان

  • T Zeyen
  • K Vandenberghe
چکیده

Because two similar transscleral cyclophotocoagulation diode lasers with identical power & duration settings induced significantly different postoperative inflammation, we wanted to compare the real output of both lasers. Using a Power/Energy Meter (Fieldmaster) we compared the output of the two lasers (the Iridis [Quantel Medical] and the Iris Medical [OcuLight SLx]) at different energy levels. At a setting of 600, 1000, 1400, 1700, 2000 and 2500 mW, the measured output for the Iridis and Iris Medical diode laser were respectively 685 and 400 mW, 970 and 650 mW, 1470 and 875 mW, 1700 and 1000 mW, and 1990 compared to 1000 mW. On the average the output of the Iridis laser was correct and the output of the Iris Medical laser was 40% lower than the setting. Overtreatment and severe complications occurred with the Iridis laser because the manufacturer recommended using wrong power settings based on the Iris Medical laser, which was undercalibrated. The calibration of cyclophotocoagulation diode lasers should be performed prior to use when changing to a new device and whenever over- or undertreatment is observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trans-scleral Diode Laser Cyclophotocoagulation in Children with Refractory Glaucoma. Long-term Outcomes

The aim of this study was to evaluate the efficacy of diode laser cyclophotocoagulation in paediatric patients with refractory glaucoma and to assess complications associated with this method. The study included 69 eyes in 53 children with uncontrolled refractory glaucoma who underwent diode laser cyclophotocoagulation (cyclodiode) treatment. The mean age of this group was 6.1 years (range, 0.9...

متن کامل

Long-Term Outcome of Transscleral Diode Laser Cyclophotocoagulation for Refractory Glaucoma

Objective: To study success rate and long term efficacy and complications of the transscleral diode laser Cyclophotocoagulation in refractory glaucoma. Patients and Methods: In a noncomparative interventional case series, eyes of 9 patients with glaucoma resistant to conventional medical and surgical therapies were treated with transscleral diode laser Cyclophotocoagulation from 2004 to 2007. C...

متن کامل

Diode laser transscleral cyclophotocoagulation followed by phacotrabeculectomy on medically unresponsive acute primary angle closure eyes: the long-term result

BACKGROUND To explore the intraocular pressure-lowering effect and complications of diode laser transscleral cyclophotocoagulation (DLTSC) followed by phacotrabeculectomy on medically unresponsive acute primary angle closure eyes. METHODS Nine eyes of nine medically unresponsive acute primary angle closure patients were enrolled. All the patients underwent cyclophotocoagulation followed by ph...

متن کامل

Treatment parameters for the efficacy of transscleral cyclophotocoagulation in rabbits using a diode laser.

PURPOSE To determine parameters for the efficacy of transscleral cyclophotocoagulation (TSCPC) using a diode laser. METHODS We performed TSCPC on 74 pigmented rabbits with different exposure powers and varying number of applications, followed by clinical observation and histological examination up to 24 weeks. RESULTS Based on observation of the clinical course, the most favorable parameter...

متن کامل

Diode laser assisted endodontic treatments in periapical lesions repair: case series

Background and Aim: Bacterial disinfection is considered as the primary etiology of pulpal and periapical lesions and as the result, adequate elimination of such infections is one of the purposes of root canal treatment; But since this purpose is impossible to achieve, reducing the bacterial load seems to be as a rational goal. Diode lasers have made their way into endodontics for better disinf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bulletin de la Societe belge d'ophtalmologie

دوره 292  شماره 

صفحات  -

تاریخ انتشار 2004