Ocular anterior segment biometry and high-order wavefront aberrations during accommodation.

نویسندگان

  • Yimin Yuan
  • Yilei Shao
  • Aizhu Tao
  • Meixiao Shen
  • Jianhua Wang
  • Guohua Shi
  • Qi Chen
  • Dexi Zhu
  • Yan Lian
  • Jia Qu
  • Yudong Zhang
  • Fan Lu
چکیده

PURPOSE We investigated the relationships between the ocular anterior segment biometry and the ocular high-order aberrations (HOAs) during accommodation by combined ultralong scan depth optical coherence tomography (UL-OCT) and wavefront sensor. METHODS We enrolled 35 right eyes of young healthy subjects (21 women and 14 men; age, 25.6 ± 3.1 years; spherical equivalent refractive error, -0.41 ± 0.59 diopters [D]). A custom-built UL-OCT and a wavefront sensor were combined. They were able to image the ocular anterior segment and to measure the HOAs during accommodation. The differences in the biometric dimensions and in the HOAs between the nonaccommodative and accommodative states were compared, and the relationships between them were investigated. RESULTS Compared to the nonaccommodative condition, anterior chamber depth, pupil diameter, and radii of the crystalline lens surface curvatures decreased significantly, while the lens thickness and root-mean-square of high-order aberration (HORMS) of fixed 3-mm pupil size increased under the accommodative stimulus (P < 0.01). A negative correlation was found between the change in the radius of the lens anterior surface curvature and the change in HORMS (r = -0.370, P = 0.014). For nonaccommodative and accommodative conditions, HORMS for a fixed pupil size was correlated negatively with pupil diameter (r = -0.532 and -0.801, respectively, P < 0.01). CONCLUSIONS The anterior segment biometry and the HOAs changed significantly during accommodation. The increase in HOAs mainly was due to the increased convexity of the anterior surface of the lens during accommodation. Contraction of the pupil may help to decrease HOAs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of ocular anterior segment dimension and wavefront aberration simultaneously during accommodation.

In order to understand the relationship between accommodation and vision quality, a custom-built ultra-long scan depth spectral domain optical coherence tomography (UL-SDOCT) and a Shack-Hartmann wavefront sensor (HSWFS) were combined. The resolution and scan depth of UL-SDOCT are 6 μm and 15.6 mm, respectively, which allow for high-resolution imaging of the whole anterior segment. The HSWFS co...

متن کامل

Dynamic changes in ocular Zernike aberrations and tear menisci measured with a wavefront sensor and an anterior segment OCT.

PURPOSE To measure dynamic change characteristics of spatial and temporal variations in the post-blink tear film of normal eyes. METHODS A wavefront sensor was used to measure dynamic changes in wavefront aberrations, up to the seventh order, for 10 seconds in a group of 33 normal young adults. Tear menisci were imaged with an anterior segment optical coherence tomography (AS-OCT) system and ...

متن کامل

Simultaneous real-time imaging of the ocular anterior segment including the ciliary muscle during accommodation

We demonstrated a novel approach of imaging the anterior segment including the ciliary muscle using combined and synchronized two spectral domain optical coherence tomography devices (SD-OCT). In one SD-OCT, a Complementary Metal-Oxide-Semiconductor Transistor (CMOS) camera and an alternating reference arm was used to image the anterior segment from the cornea to the lens. Another SD-OCT for im...

متن کامل

The effect of ocular aberrations on steady-state errors of accommodative response.

It is well accepted that the accommodation system is characterized by steady-state errors in focus. The purpose of this study was to correlate these errors with changes in ocular wavefront aberration and corresponding image quality when accommodating. A wavefront analyzing system, the Complete Ophthalmic Analysis System (COAS), was used in conjunction with a Badal optometer to allow continuous ...

متن کامل

The Wavefront Revolution in Cataract Surgery

Emergence of Wavefronts The concept of wavefronts refers to waves of light like flat waves on a surface of water. A perfect lens will transform these flat waves into spherical waves with a centre in the focal point, and vice versa. An imperfect lens, on the other hand, will distort these wave patterns and superimpose distortions on these perfect patterns. These distortions are called the wavefr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 54 10  شماره 

صفحات  -

تاریخ انتشار 2013