Degree of conversion of nanofilled and microhybrid composite resins photo-activated by different generations of LEDs

نویسندگان

  • Benicia Carolina Iaskieviscz RIBEIRO
  • Juliana Maria Capelozza BOAVENTURA
  • Joel de BRITO-GONÇALVES
  • Alessandra Nara de Souza RASTELLI
  • Vanderlei Salvador BAGNATO
  • José Roberto Cury SAAD
چکیده

OBJECTIVE This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs). MATERIAL AND METHODS Filtek™ Z350 nanofilled composite resins and Amelogen® Plus, Vit-l-escence™ and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free Light™ 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm(-1)) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). RESULTS The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukey’s test showed that the nanofilled resin (Filtek™ Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (Filtek™ Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free Light™ 2). CONCLUSIONS The nanofilled resin showed the lowest DC, and the Vit-l-escence™ microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Knoop microhardness and FT-Raman evaluation of composite resins: influence of opacity and photoactivation source.

The aim of this study was to evaluate the degree of conversion by Knoop microhardness (KHN) and FT-Raman spectroscopy (FTIR) of one nanofilled (Filtek Supreme-3M-ESPE [FS]) and one microhybrid composite (Charisma-Heraeus-Kulzer [CH]), each with different opacities, namely enamel, dentin, and translucent, which were photo-activated by a quartz-tungsten-halogen lamp (QTH) and a light-emitting dio...

متن کامل

Influence of different shades and LED irradiance on the degree of conversion of composite resins.

The aim of this study was to evaluate the degree of conversion (DC) of two composite resins with different shades that were light cured by light-emitting diodes (LEDs) of different irradiances. Specimens (5 mm ' 2 mm) were prepared with a nanofilled (Filtek Supreme - A2E, A2D, and WE) or microhybrid resin (Opallis - A2E, A2D, and EBleach Low) and were randomly divided into 12 groups (n = 5 each...

متن کامل

بررسی درجه تبدیل کامپوزیت‌های میکروهیبرید، نانوهیبرید و Ormocer با استفاده از سیستم‌های نوردهی LED وQTH

Background and Aims: The aim of this study was to measure the degree of conversion (DC) of three types of composite resins (micro-hybrid, nano-hybrid and Ormocer) with different light curing units (LED LCU and QTH LCU) in two depths. Materials and Methods: Three commercially available dental resin composites were used in this study: (Tetric Ceram, Ivoclar Vivadent, Liechtenstein-A2 shade), (Te...

متن کامل

Impact of filler size and distribution on roughness and wear of composite resin after simulated toothbrushing

OBJECTIVES Nanofilled composite resins are claimed to provide superior mechanical properties compared with microhybrid resins. Thus, the aim of this study was to compare nanofilled with microhybrid composite resins. The null hypothesis was that the size and the distribution of fillers do not influence the mechanical properties of surface roughness and wear after simulated toothbrushing test. ...

متن کامل

Surface roughness of composite resins subjected to hydrochloric acid.

The purpose of this study was to determine the influence of hydrochloric acid on surface roughness of composite resins subjected to brushing. Sixty samples measuring 2 mm thick x 6 mm diameter were prepared and used as experimental units. The study presented a 3x2 factorial design, in which the factors were composite resin (n=20), at 3 levels: microhybrid composite (Z100), nanofilled composite ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2012