The effect of starting point placement technique on thoracic transverse process strength: an ex vivo biomechanical study
نویسندگان
چکیده
BACKGROUND The use of thoracic pedicle screws in spinal deformity, trauma, and tumor reconstruction is becoming more common. Unsuccessful screw placement may require salvage techniques utilizing transverse process hooks. The effect of different starting point placement techniques on the strength of the transverse process has not previously been reported. The purpose of this paper is to determine the biomechanical properties of the thoracic transverse process following various pedicle screw starting point placement techniques. METHODS Forty-seven fresh-frozen human cadaveric thoracic vertebrae from T2 to T9 were disarticulated and matched by bone mineral density (BMD) and transverse process (TP) cross-sectional area. Specimens were randomized to one of four groups: A, control, and three others based on thoracic pedicle screw placement technique; B, straightforward; C, funnel; and D, in-out-in. Initial cortical bone removal for pedicle screw placement was made using a burr at the location on the transverse process or transverse process-laminar junction as published in the original description of each technique. The transverse process was tested measuring load-to-failure simulating a hook in compression mode. Analysis of covariance and Pearson correlation coefficients were used to examine the data. RESULTS Technique was a significant predictor of load-to-failure (P = 0.0007). The least squares mean (LS mean) load-to-failure of group A (control) was 377 N, group B (straightforward) 355 N, group C (funnel) 229 N, and group D (in-out-in) 301 N. Significant differences were noted between groups A and C, A and D, B and C, and C and D. BMD (0.925 g/cm2 [range, 0.624-1.301 g/cm2]) was also a significant predictor of load-to-failure, for all specimens grouped together (P < 0.0001) and for each technique (P <0.05). Level and side tested were not found to significantly correlate with load-to-failure. CONCLUSIONS The residual coronal plane compressive strength of the thoracic transverse process is dependent upon the screw starting point placement technique. The funnel technique significantly weakens transverse processes as compared to the straightforward technique, which does not significantly weaken the transverse process. It is also dependent upon bone mineral density, and low failure loads even in some control specimens suggest limited usefulness of the transverse process for axial compression loading in the osteoporotic thoracic spine.
منابع مشابه
Effect of Pretreatment with Fluoride, Chlorhexidine, and Mixed Fluoride-Chlorhexidine Gels on Shear Bond Strength of Orthodontic Brackets: An Ex-Vivo Study
Background and Aim: Orthodontic patients are at an increased risk of caries due to difficulty in plaque control. Antimicrobial agents, such as fluoride and chlorhexidine, can be useful in preventing tooth demineralization. The present study aimed to determine the effect of fluoride and chlorhexidine gels and their mixture on the shear bond strength (SBS) of orthodontic brackets. Materials and ...
متن کاملBiomechanical study of the funnel technique applied in thoracic pedicle screw replacement.
BACKGROUND Funnel technique is a method used for the insertion of screw into thoracic pedicle. AIM To evaluate the biomechanical characteristics of thoracic pedicle screw placement using the Funnel technique, trying to provide biomechanical basis for clinical application of this technology. METHODS 14 functional spinal units (T6 to T10) were selected from thoracic spine specimens of 14 fres...
متن کاملEvaluation of the Effect of Ursolic Acid Compared with Ibuprofen and Dexamethasone in Synoviocyte Model for Osteoarthritis: an Ex Vivo Study
Background: Osteoarthritis is one of the most commonly diagnosed malignant diseases in the world and was previously recognized as a degenerative joint disease characterized by cartilage deformity and the formation of new bones at the edges of the joint. But this disease is not just a degenerative disease but also a biomechanical, biochemical, and cellular phenomenon. Common treatments include s...
متن کاملColorimetric Comparison of Tooth Color Change Following the Use of Two Endodontic Sealers: An Ex-Vivo Study
Background and Aim: Tooth discoloration induced by endodontic sealers is an un-desired outcome of endodontic treatment that affects the esthetic appearance of the teeth, which is important especially in the anterior region. The aim of the present study was to compare the coronal discoloration caused by two frequently used resin-based sealers namely EasySeal and AdSeal. Materials and Methods: F...
متن کاملAn ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty.
STUDY DESIGN Comparative ex vivo biomechanical study. OBJECTIVE To determine the strength and stiffness of osteoporotic vertebral bodies subjected to compression fractures and stabilized via bipedicular injections of the following: 1) Simplex P (Stryker-Howmedica-Osteonics, Rutherford, NJ), 2) Simplex P formulated consistent with the practice of vertebroplasty (F2), or 3) BoneSource (Stryker-...
متن کامل