Patient dose measurement in common medical X‐ray examinations in Iran
نویسندگان
چکیده
The main purpose of this study was to investigate patient dose in the chest (PA/AP/LAT) and skull (PA/AP/LAT) X-ray examinations, as frequent procedures. The study was performed in eight public hospitals of Khuzestan province, Iran. Patient dosimetry was conducted on 567 standard patient X-ray examinations (males: 61.2%, female: 38.2%). Dosimetry protocol in this study was indirect method, according to the International Atomic Energy Agency (IAEA) Technical Reports series No.457. Patients weighing 70 ± 10 kg were considered as standard. In the indirect dosimetry approach, exposure parameters such as kVp, mAs, focal film distance (FFD), and tube outputs recorded during data acquisition were used for calculating incident air kerma on the patient's skin, entrance surface air kerma (ESAK) that is recommended by the IAEA as the most appropriate patient dosimetry quantity in simple radiographic examinations. This survey reveals significant variations in the radiological practice. Results showed that the parameters set by radiologic technologists change in a wide range: mAs varied from 2 to 80 for skull PA, 2 to 202 for chest LAT, and FFD varied from 50 to 180 for skull LAT projection. The study showed that patient doses in three chest projections exceed the IAEA and European Commission dose reference levels (EC DRLs) - 1.0, 1.12, and 2.20 mGy for chest PA, chest AP, and chest LAT, respectively. Results also showed that mean ESAKs of patients in skull projections were generally lower than the IAEA and EC DRLs, 1.5, 1.72, and 2.25 for skull LAT, skull AP, and skull PA, respectively. This study provides evidence that dose reduction in the simple X-ray examinations is feasible by updating clinical audits and implementation of systematic quality assurance (QA) and quality control (QC) programs. The authors recommend that DRLs obtained in this study can be used as local DRLs in Khuzestan area and dose surveys must be performed in all provinces to establish national dose reference levels (NDRLs) in Iran.
منابع مشابه
Patient dose in routine X-ray examinations in Yazd state
Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...
متن کاملLocal Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran
Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...
متن کاملEvaluation of Organ and Effective Doses to Patients Arising From Some Common X-Ray Examinations by PCXMC Program in Sabzevar, Iran
Introduction The purpose of this study was to estimate organ and effective doses in patients undergoing some common X-ray examinations in Sabzevar, Iran. The effective dose is one of the best parameters for describing the amount of radiation dose received by a patient undergoing any diagnostic X-ray examination. The public dose from X-ray examinations depends on various factors, and its contrib...
متن کاملExcess Cancer Risk Assessment from Some Common X-Ray Examinations in Sabzevar County
Introduction: Nowadays ionizing radiation has a considerable contribution in medical diagnostic and treatment. Using ionizing radiation is increasing rapidly, so biological effects of ionizing radiation should be considered more. X-rays in the range of diagnostic radiology have hazardous effects and risks that are defined as random effects. These effects obey the LNT hypothesis that occur at lo...
متن کاملEntrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals
Background: There is not any report on the radiation doses received by patients in diagnostic radiology sections in hospitals under control of Chaharmahal and Bakhtiari Medical Sciences University, in the south west of Iran. Objectives: The aim of this study is measurement of entrance surface doses (ESD) for the most routine types of X-ray procedures in radiology centers as part of ongoing d...
متن کاملRadiation exposure of the Yazd population from medical conventional X-ray examinations
Background: Radiation dose knowledge through Xray examinations and their distribution in Iran provides useful guidance on patient dose reduction. The results of the entrance skin dose (ESDs) of five common radiographies in all radiology centers in Yazd province were reported in our previous study (2003). In the present study we have evaluated the collective effective dose of convention...
متن کامل