The imaging characteristics of an arc-shaped xenon gas ionization chamber for the purpose of megavoltage CT imaging were investigated. The detector consists of several hundred 320 microm thick gas cavities separated by thin tungsten plates of the same thickness. Dose response, efficiency and resolution parameters were calculated using Monte Carlo simulations. The calculations were compared to measurements taken in a 4 MV photon beam, assuming that the measured signal in the chambers corresponds to the therein absorbed dose. The measured response profiles for narrow and broad incident photon beams could be well reproduced with the Monte Carlo calculations. They show, that the quantum efficiency is 29.2% and the detective quantum efficiency at zero frequency DQE(0) is 20.4% for the detector arc placed in focus with the photon source. For a detector placed out of focus, these numbers even increase. The efficiency of this kind of radiation detector for megavoltage radiation therefore surpasses the reported efficiency of existing detector technologies. The resolution of the detector is quantified with calculated and measured line spread functions. The corresponding modulation transfer functions were determined for different thicknesses of the tungsten plates. They show that the resolution is only slightly dependent on the plate thickness but is predominantly determined by the cell size of the detector. The optimal plate thickness is determined by a tradeoff between quantum efficiency, total signal generation and resolution. Thicker plates are more efficient but the total signal and the resolution decrease with plate thickness. In conclusion, a gas ionization chamber of the described type is a highly efficient megavoltage radiation detector, allowing to obtain CT images with very little dose for a sufficient image quality for anatomy verification. This kind of detector might serve as a model for a future generation of highly efficient radiation detectors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of ScintSim1 and Geant4 Monte Carlo simulation codes for optical photon transport in thick segmented scintillator arrays

  Introduction: Arrays of segmented scintillation crystals are useful in megavoltage x-ray imaging detectors for image-guided radiotherapy. Most previous theoretical studies on these detectors have modelled only ionizing-radiation transport. Scintillation light also affects detector performance. ScintSim1, our previously reported optical Monte Carlo code for such detector...

متن کامل

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

A performance study of the conceptual implementation of the GEM-tracking detector in Monte Carlo simulation

  PANDA experiment (antiProton ANnihilation at DArmstadt) is one of the key projects of the future FAIR facilities to investigate the reactions of antiprotons with protons and nuclear targets.   experiment is designed to serve as a completely extraordinary physical potential due to exploiting the availability of cold and high-intensity beams of antiprotons. One of the significant parts of the  ...

متن کامل

Monte Carlo calculation of shielding properties of newly developed heavy concretes for megavoltage photon beam spectra used in radiation therapy

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

متن کامل

Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study

Background: Obtaining high quality images in Single Photon Emission Tomography (SPECT) device  is the most important goal in nuclear medicine. Because if image quality is low, the possibility of making a mistake in diagnosing and treating the patient will rise. Studying effective factors in spatial resolution of imaging systems is thus deemed to be vital. One of the most important factors in S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 29 2  شماره 

صفحات  -

تاریخ انتشار 2002