Patient-ventilator interaction: the last 40 years.
نویسنده
چکیده
Patient-ventilator synchrony is a complex issue affected by ventilator performance, patient characteristics, and the patient-ventilator interface. The history of patient-ventilator interaction includes avoidance of pharmacalogic paralysis, the development of spontaneous breathing systems, microprocessor technology to maximize interaction, and closed-loop control. While most clinicians agree that patient-ventilator synchrony is desirable, there remain no cause-and-effect data that asynchrony is associated with poor outcome.
منابع مشابه
Patient-Ventilator Interaction During Noninvasive Ventilation in Simulated COPD.
BACKGROUND During noninvasive ventilation (NIV) of COPD patients, delayed off-cycling of pressure support can cause patient ventilator mismatch and NIV failure. This systematic experimental study analyzes the effects of varying cycling criteria on patient-ventilator interaction. METHODS A lung simulator with COPD settings was connected to an ICU ventilator via helmet or face mask. Cycling was...
متن کاملTranscutaneous electromyographic respiratory muscle recordings to quantify patient–ventilator interaction in mechanically ventilated children
BACKGROUND To explore the feasibility of transcutaneous electromyographic respiratory muscle recordings to automatically quantify the synchronicity of patient-ventilator interaction in the pediatric intensive care unit. METHODS Prospective observational study in a tertiary paediatric intensive care unit in an university hospital. Spontaneous breathing mechanically ventilated children < 18 yea...
متن کاملAutomated detection of patient-ventilator asynchrony: new tool or new toy?
Although severe patient-ventilator asynchrony is frequent during invasive and non-invasive mechanical ventilation, diagnosing such asynchronies usually requires the presence at the bedside of an experienced clinician to assess the tracings displayed on the ventilator screen, thus explaining why evaluating patient-ventilator interaction remains a challenge in daily clinical practice. In the prev...
متن کاملClinical review: Patient-ventilator interaction in chronic obstructive pulmonary disease
Mechanically ventilated patients with chronic obstructive pulmonary disease often prove challenging to the clinician due to the complex pathophysiology of the disease and the high risk of patient-ventilator asynchrony. These problems are encountered in both intubated patients and those ventilated with noninvasive ventilation. Much knowledge has been gained over the years in our understanding of...
متن کاملClosed-loop control of mechanical ventilation: description and classification of targeting schemes.
There has been a dramatic increase in the number and complexity of new ventilation modes over the last 30 years. The impetus for this has been the desire to improve the safety, efficiency, and synchrony of ventilator-patient interaction. Unfortunately, the proliferation of names for ventilation modes has made understanding mode capabilities problematic. New modes are generally based on increasi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 56 1 شماره
صفحات -
تاریخ انتشار 2011