A review of outcomes and modes of presentation following liner dissociation from Harris-Galante uncemented acetabular components.
نویسندگان
چکیده
PURPOSE Dissociation of the polyethylene liner is a known failure mechanism of the Harris Galante I and II uncemented acetabular components. The outcomes of revision surgery for this indication and the influence of time to diagnosis are not well described. METHODS We report a series of 29 cases revised due to this failure mechanism. The median time from primary to revision surgery was 13 years. RESULTS At a median of 4 years follow-up, the mean OHS was 34 (range 6-48) but results were poorer (mean 29; range 6-45) when the diagnosis and revision was delayed compared to when it was not (mean 39; range 20-48). A large proportion of our patients (n = 14) presented with sudden onset of symptoms with or without trauma. Osteolysis was common in this series but the cup was well fixed in 20/29 cases. There was macroscopic damage to the shell in all cases. CONCLUSIONS In our experience, prompt revision of liner dissociation optimises outcomes in this group of patients and radiology reporting alone is not sufficient to identify these cases.
منابع مشابه
The Harris-Galante porous-coated, hemispherical, polyethylene-lined acetabular component in patients under 50 years of age: a 12- to 16-year review.
We have reviewed 70 Harris-Galante uncemented acetabular components implanted as hybrid hip replacements with cemented stems between 1991 and 1995 in 53 patients whose mean age was 40 years (19 to 49). The mean follow-up was for 13.6 years (12 to 16) with no loss to follow-up. We assessed the patients both clinically and radiologically. The mean Oxford hip score was 20 (12 to 46) and the mean H...
متن کاملHarris-Galante II acetabular cup: a survival analysis.
PURPOSE To determine the survival rate of the Harris-Galante (HG) II cup and identify factors contributing to failure. METHODS 271 primary total hip arthroplasties (THAs) performed between 1992 and 1999 in our hospitals using the HG II acetabular cup were retrospectively reviewed due to a high incidence of liner dissociation. RESULTS 48 THAs were revised, 32 (67%) of which were due to liner...
متن کاملRevision of an acetabular liner has a high risk of dislocation.
Polyethylene liners of modular acetabular components wear sometimes need to be replaced, despite the metal shell being well fixed. Replacing the liner is a relatively simple procedure, but very little is known of the outcome of revision. We prospectively followed up 1126 Harris-Galante I metal-backed, uncemented components for between nine and 19 years. We found 38 (3.4%) liners of 1126 acetabu...
متن کاملFixation of ultrahigh-molecular-weight polyethylene liners to metal-backed acetabular cups.
Locking mechanisms and metal-liner interface surfaces of six modular acetabular systems were evaluated to determine their effect on micromotion and backside wear of the polyethylene liner. Rotational and axial motion between the metal shell and polyethylene liner was measured in the Duraloc (DePuy, Warsaw, IN), Harris-Galante (Zimmer, Warsaw, IN), Impact (Biomet, Warsaw, IN), Lip Loc (Biomet), ...
متن کاملHarris Galante cementless acetabular replacement in avascular necrosis.
We describe the results of 76 total arthroplasties of the hip for stage-III or stage-IV avascular necrosis of the femoral head. Harris Galante Porous cups were used in 63 patients between 1986 and 1994 and followed prospectively. We reviewed 70 hips with a follow-up of more than five years (mean 7.6). At the latest review the mean Harris Hip Score had improved from a preoperative value of 29 +/...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hip international : the journal of clinical and experimental research on hip pathology and therapy
دوره 26 2 شماره
صفحات -
تاریخ انتشار 2016