High-resolution three-dimensional extracellular recording of neuronal activity with microfabricated electrode arrays.

نویسندگان

  • Jiangang Du
  • Ingmar H Riedel-Kruse
  • Janna C Nawroth
  • Michael L Roukes
  • Gilles Laurent
  • Sotiris C Masmanidis
چکیده

Microelectrode array recordings of neuronal activity present significant opportunities for studying the brain with single-cell and spike-time precision. However, challenges in device manufacturing constrain dense multisite recordings to two spatial dimensions, whereas access to the three-dimensional (3D) structure of many brain regions appears to remain a challenge. To overcome this limitation, we present two novel recording modalities of silicon-based devices aimed at establishing 3D functionality. First, we fabricated a dual-side electrode array by patterning recording sites on both the front and back of an implantable microstructure. We found that the majority of single-unit spikes could not be simultaneously detected from both sides, suggesting that in addition to providing higher spatial resolution measurements than that of single-side devices, dual-side arrays also lead to increased recording yield. Second, we obtained recordings along three principal directions with a multilayer array and demonstrated 3D spike source localization within the enclosed measurement space. The large-scale integration of such dual-side and multilayer arrays is expected to provide massively parallel recording capabilities in the brain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Innovative Methodology High-Resolution Three-Dimensional Extracellular Recording of Neuronal Activity With Microfabricated Electrode Arrays

Du J, Riedel-Kruse IH, Nawroth JC, Roukes ML, Laurent G, Masmanidis SC. High-resolution three-dimensional extracellular recording of neuronal activity with microfabricated electrode arrays. J Neurophysiol 101: 1671–1678, 2009. First published December 17, 2008; doi:10.1152/jn.90992.2008. Microelectrode array recordings of neuronal activity present significant opportunities for studying the brai...

متن کامل

Multi-electrode arrays technology for the non-invasive recording of neural signals: a review article

The recording of electrophysiological activities of brain neurons in the last half-century has been considered as one of the effective tools for the development of neuroscience. One of the techniques for recording the activity of nerve cells is the multi-electrode arrays (MEAs). Microelectrode arrays (MEAs) are usually employed to record electrical signals from electrogenic cells like neurons o...

متن کامل

Neural recording and stimulation of dissociated hippocampal cultures using microfabricated three-dimensional tip electrode array.

There is increasing interest in interfacing dissociated neuronal cultures with planar multielectrode arrays (MEAs) for the study of the dynamics of neuronal networks. Here we report on the successful use of three-dimensional tip electrode arrays (3D MEAs), originally developed for use with brain slices, for recording and stimulation of cultured neurons. We observed that many neurons grew direct...

متن کامل

In vivo neuronal action potential recordings via three-dimensional microscale needle-electrode arrays

Very fine needle-electrode arrays potentially offer both low invasiveness and high spatial resolution of electrophysiological neuronal recordings in vivo. Herein we report the penetrating and recording capabilities of silicon-growth-based three-dimensional microscale-diameter needle-electrodes arrays. The fabricated needles exhibit a circular-cone shape with a 3-μm-diameter tip and a 210-μm len...

متن کامل

Massively parallel recording of unit and local field potentials with silicon-based electrodes.

Parallel recording of neuronal activity in the behaving animal is a prerequisite for our understanding of neuronal representation and storage of information. Here we describe the development of micro-machined silicon microelectrode arrays for unit and local field recordings. The two-dimensional probes with 96 or 64 recording sites provided high-density recording of unit and field activity with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurophysiology

دوره 101 3  شماره 

صفحات  -

تاریخ انتشار 2009