A Single-Stage Repair of Arch and Descending Thoracic Aortic Aneurysms Using Jotec E-vita Open Plus Hybrid Stent Graft Combined With Antegrade Deployment of Thoracic Endograft.

نویسندگان

  • Mohamad Bashir
  • Matthew Fok
  • Richard G McWilliams
  • Michael Desmond
  • Mark Field
  • Robert K Fisher
  • Aung Oo
  • Manoj Kuduvalli
چکیده

We report a unique case of a 63-year-old female with extensive peripheral vascular disease who underwent a single-stage surgical repair of the aortic arch and descending thoracic aortic aneurysm utilizing the Jotec E-vita Open Plus hybrid stent graft system combined with antegrade deployment of a thoracic endograft via a median sternotomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One-stage repair in complex multisegmental thoracic aneurysmal disease: results of a multicentre study.

OBJECTIVES Patients with thoracic aneurysmal disease involving the arch and the descending or thoracoabdominal aorta may require more than one surgical intervention. The results of one-stage repair using a hybrid stent-graft in the frozen elephant trunk manner are presented. METHODS Between January 2005 and March 2012, 113 (age 67 ± 10 years) of 358 registered patients in the International E-...

متن کامل

Hybrid arch debranching and endograft repair in a patient with a ruptured thoracic aortic aneurysm.

Recent advances in hybrid techniques of aortic arch debranching allow for the repair of thoracic aortic arch aneurysm without requiring cardiopulmonary bypass or hypothermic circulatory arrest. We describe the repair of a ruptured proximal descending thoracic aortic aneurysm, using off-pump aortic arch debranching and antegrade transaortic deployment of a thoracic endograft in an elderly patient.

متن کامل

Total aortic arch replacement with a novel four-branched frozen elephant trunk graft: first-in-man results.

OBJECTIVES The combined disease of the aortic arch and the proximal descending aorta remains a surgical challenge. With the 'frozen elephant technique', the ascending aorta, along with the aortic arch, is replaced conventionally and an endovascular stent graft is placed into the descending aorta in the antegrade manner through the open aortic arch, thereby potentially allowing for a 'single-sta...

متن کامل

Hybrid antegrade repair of the arch and descending thoracic aorta with a new integrated stent-Dacron graft in acute type A aortic dissection: a look into the future with new devices.

A young male patient underwent supracoronary replacement of the ascending aorta for acute type A dissection under hypothermic circulatory arrest. After discharge, he was readmitted two weeks later due to severe aortic regurgitation and acute arch redissection. Under a second period of hypothermic circulatory arrest three weeks after the initial operation, radical treatment with aortic valve rep...

متن کامل

Single-stage, off-pump hybrid repair of extensive aneurysms of the aortic arch and the descending thoracic aorta.

S urgical treatment of aortic arch aneurysms has been challenging. These aneurysms are usually treated with open surgical repair that requires cardiopulmonary bypass (CPB) and hypothermic circulatory arrest (HCA). Furthermore, in cases of aneurysms involving both the aortic arch and the descending thoracic aorta (DTA) extensive surgical incisions or staged procedures are often necessary, increa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Aorta

دوره 1 4  شماره 

صفحات  -

تاریخ انتشار 2013