First clinical implementation of the Capri applicator

نویسنده

  • Aime M. Gloi
چکیده

This study was to assess the Capri applicator for patients with endometrial cancer undergoing high-radiation dose treatments following external-beam radiation therapy. The Capri applicator is an inflatable vaginal cylinder with multiple channels. It is used to tailor the dose distribution to an asymmetric vaginal disease, and better spare organs at risk. Five patients with high-risk endometrial cancer were selected for this study. The patients were treated with a high dose of radiation using the Capri applicator: daily fraction of 7 Gy was prescribed for a total dose of 21Gy. The treatment plans included radiobiological parameters such as equivalent uniform dose (EUD), normal tissue complication probability (NTCP), and tumor control probability (TCP). Based on the dose-volume histograms (DVH), we also calculated four quality factors: conformity index (CI), dose homogeneity index (DHI), dose nonuniformity index (DNR), and overdose index (OI). The TCP values range from 82.26% to 95.92%. Very low values of NTCP were observed for the bladder and rectum. The EUDs to organs at risk ranged from 4.65 Gy to 18.22 Gy for the bladder, and from 3.41 Gy from to 6.56 Gy for the rectum. The mean CI was 1.05 (SD = 0.0008). The mean DNR was 0.10 (range 0.0-0.295, SD= 0.100). The mean OI was 0.019 (SD = 0.028). The DHIs were in the range of 1.0-0.754 (mean 0.886, SD = 0.116). The use of a multichannel vaginal cylinder may not only help cover extensive vaginal disease, but also reduce the dose to the rectum. This dosimetric analysis shows that rectal doses could be reduced using a multichannel cylinder. However, the dose delivered to the bladder based on EUD calculation may be higher than that obtained with other methods. Each patient must be evaluated independently to determine if a multichannel treatment is appropriate. Clinical followup will show whether this rectal dose sparing translates into a real toxicity improvement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Commissioning the First Mobile Dedicated Accelerator for Intraoperative Electron Radiotherapy in Iran

Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employe...

متن کامل

ارزیابی آلودگی فوتونی اپلیکاتور Beam Shaper با استفاده از شبیه سازی مونت ‌کارلو

Background and purpose: Beam shaper is a type of applicator used in conjunction with the intraoperative electron radiotherapy. This study aimed at quantitative evaluation of the photon contamination of this applicator using Monte Carlo simulation. Materials and methods: In this experimental study, at first the head of LIAC accelerator was simulated along with the beam shaper applicator using...

متن کامل

Study of dosimetric and spatial variations due to applicator positioning during inter-fraction high-dose rate brachytherapy in the treatment of carcinoma of the cervix: A three dimensional dosimetric analysis

Background: This study evaluates dosimetric and spatial variations in inter–fraction applicator positioning in high dose rate (HDR) brachytherapy. Materials and Methods: This study includes 25 retrospective patients of carcinoma of the cervix. Each patient received 5 fractions of HDR intracavitary brachytherapy. High Risk-Clinical Target Volume (HR-CTV) were drawn on CT images. First impl...

متن کامل

Investigation of Anisotropy Caused by Cylinder Applicator on Dose Distribution around Cs-137 Brachytherapy Source using MCNP4C Code

Introduction: Brachytherapy is a type of radiotherapy in which radioactive sources are used in proximity of tumors normally for treatment of malignancies in the head, prostate and cervix. Materials and Methods: The Cs-137 Selectron source is a low-dose-rate (LDR) brachytherapy source used in a remote afterloading system for treatment of different cancers. This system uses active and inactive sp...

متن کامل

Clinical implementation of MR‐guided vaginal cylinder brachytherapy

We present an institutional experience on the clinical implementation of magnetic resonance (MR)-guided vaginal brachytherapy using commercially available solid applicator models. To test the fidelity of solid applicator models to digitize vaginal cylinder applicators, three datasets were evaluated. The first included 15 patients who were simulated with CT alone. Next, a water phantom was used ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014