SU-E-T-458: Radiobiological Comparison of Single and Dual-Isotope Prostate Seed Implants.

نویسندگان

  • C Knaup
  • P Mavroidis
  • C Esquivel
  • S Stathakis
  • G Swanson
  • N Papanikolaou
چکیده

PURPOSE Several isotopes are available for low dose-rate brachytherapy of the prostate. Currently, most implants use a single isotope. However, the use of dual-isotope implants may yield an advantageous combination of characteristics such as half-life and relative biological effectiveness. However, the use of dual-isotope implants complicates treatment planning and quality assurance. Do the benefits of dual-isotope implants outweigh the added difficulty? The goal of this work was to use a linear-quadratic model to compare single and dual-isotope implants. METHODS Ten patients were evaluated in this study. For each patient, six treatment plans were created with single or dual-isotope combinations of 1251, 103Pd and 131Cs. For each plan the prostate, urethra, rectum and bladder were contoured by a physician. The biologically effective dose was used to determine the tumor control probability and normal tissue complication probabilities for each plan. Each plan was evaluated using favorable, intermediate and unfavorable radiobiological parameters. The results of the radiobiological analysis were used to compare the single and dual-isotope treatment plans. RESULTS Iodine-125 only implants were seen to be most affected by changes in tumor aggressiveness. Significant differences in organ response probabilities were seen at common dose levels. It was recognized that these differences were likely a result of suboptimal initial seed strengths. After adjusting the initial seed strength to maximize complication-free tumor control the differences between isotope combinations were minimal. This result was true even for unfavorable tumors. CONCLUSIONS The objective of this work was to perform a radiobiologically based comparison of single and dual-isotope prostate seed implant plans. For all isotope combinations, the plans were improved by varying the initial seed strength. For the minimally-optimized treatment plans, no substantial differences in predicted treatment outcomes were seen among the different isotope combinations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SU-E-T-465: Exploring the Dosimetric and Tumor Control Consequences of Prostate Seed Loss and Migration.

PURPOSE Once implanted, prostate brachytherapy seeds are vulnerable to loss and movement. A general estimation of these effects may be useful for making patient care decisions when seeds are lost after the post-implant scan. The goal of this work was to explore the dosimetric and radiobiological effects of the types of seed loss and migration common in prostate brachytherapy. METHODS This stu...

متن کامل

Comparison of dosimetric and radiobiological effects of various IMRT techniques regarding to joint volume between target tissue and organs at risk in prostate cancer patients

Background: Intensity-modulated radiotherapy (IMRT) is one of the most usable methods in prostate radiotherapy that is used with different techniques. The aim of this study was to evaluate and compare the dosimetric and radiobiological effects of prostate IMRT techniques regarding to joint volume between the target tissue and organs at risk as a patients anatomical parameter. Methods: This res...

متن کامل

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

An NTCP Analysis of Urethral Complications from Low Doserate Mono- and Bi-Radionuclide Brachytherapy

Urethral NTCP has been determined for three prostates implanted with seeds based on (125)I (145 Gy), (103)Pd (125 Gy), (131)Cs (115 Gy), (103)Pd-(125)I (145 Gy), or (103)Pd-(131)Cs (115 Gy or 130 Gy). First, DU(20), meaning that 20% of the urhral volume receive a dose of at least DU(20), is converted into an I-125 LDR equivalent DU(20) in order to use the urethral NTCP model. Second, the propag...

متن کامل

Radiobiologically based treatment plan evaluation for prostate seed implants

PURPOSE Accurate prostate low dose-rate brachytherapy treatment plan evaluation is important for future care decisions. Presently, an evaluation is based on dosimetric quantifiers for the tumor and organs at risk. However, these do not account for effects of varying dose-rate, tumor repopulation and other biological effects. In this work, incorporation of the biological response is used to obta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part17  شماره 

صفحات  -

تاریخ انتشار 2012