Development, evaluation, and application of lateral-flow immunoassay (immunochromatography) for detection of rotavirus in bovine fecal samples.

نویسندگان

  • Yousif Al-Yousif
  • Joe Anderson
  • Cindy Chard-Bergstrom
  • Sanjay Kapil
چکیده

A lateral-flow immunoassay (LFT) was developed to detect bovine rotavirus in fecal samples. Using samples (n = 74) from diarrheic calves, a comparison of the LFT with a commercial latex agglutination test (LAT) and transmission electron microscopy (EM) was conducted. When EM was used as the reference method, initial studies of 29 samples indicated 70 and 80% sensitivities of the LFT and LAT, respectively, with both being 100% specific. When the LAT was the reference test, the LFT was 75% sensitive and 91% specific. Additional specimens (n = 45) were tested by the LFT and LAT alone, and results were identical for both methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Enzyme Immunoassay, Immunochromatography, and RNA-Polyacrylamide-Gel Electrophoresis for Diagnosis of Rotavirus Infection in Children with Acute Gastroenteritis

Human rotavirus is a major etiologic agent for infantile diarrhea worldwide. It is responsible for up to 3.3 million deaths per year in children in developing countries. Various rapid and sensitive techniques have been developed to readily diagnose rotavirus gastroenteritis. In the present study, we compared the sensitivity and specificity of immunochromatography and RNA-polyacrylamide-gel elec...

متن کامل

Development of a Latex Agglutination Method for Diagnosis of Rotavirus Infections

Background: Rotavirus is a major cause of morbidity and mortality among children with gastroenteritis. Since the discovery of rotaviruses, several techniques have been used for their laboratory diagnosis; those included Electron Microscopy (EM) and enzyme immunoassay. These methods, however, are expensive and not readily available everywhere. We have developed a technique which can be used for ...

متن کامل

Development of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies

Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...

متن کامل

Detection of rat, porcine, and bovine group B rotavirus in fecal specimens by solid-phase enzyme immunoassay.

An enzyme immunoassay that uses easily regenerated reagents was developed and evaluated for the ability to detect group B rotaviruses (GBR) in fecal specimens. Homologous rat GBR and heterologous porcine and bovine GBR were detected by this immunoassay, although a human GBR isolate was not. This immunoassay should prove useful in studies of GBR infections of animals.

متن کامل

Molecular typing of group A bovine rotavirus of calves in the provinces of Tehran, Alborz and Qazvin

BACKGROUND: Group A bovine rotavirus (BRV-A) is one of the most important causes of gastroenteritis and diarrhea in newborn calves. OBJECTIVES: Major types of BRV-A in Tehran, Alborz and Qazvin were detected in this study. METHODS: A total 125 fecal samples of calves showing clinical signs of diarrhea were collected from 26 industrial dairy farms located in the provinces of Tehran, Alborz and Q...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical and diagnostic laboratory immunology

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 2002