Analysis and Optimization of Quantitative Magnetization Transfer Imaging Considering the Effect of Non-Exchanging Component

نویسندگان

  • Pouria Mossahebi
  • Andrew L Alexander
  • Aaron S Field
  • Alexey A Samsonov
چکیده

INTRODUCTION: Gray matter demyelination has recently been recognized as an important pathological substrate of multiple sclerosis disease [1,2]. Magnetization transfer imaging (MTI) including both semi-quantitative (MT ratio) and quantitative (qMTI) approaches [3-6] has demonstrated high sensitivity to myelination in white matter [7,8]. Its applications to cortical gray matter characterization, however, we need to take into account additional factors related to anatomical organization of cortical GM such as partial volume effect (PVE) with CSF, the significant confounder in many qMRI techniques [9,10]. Recently, we proposed a theoretical model [11] that allows isolating a voxel compartment that is under slow or no-exchange (NE) conditions with the MT subsystem associated with the macromolecular-rich tissue. PVE with CSF may be described by such NE-compartment and hence may be potentially accounted by the qMT modeling to provide unbiased estimation of myelinsensitive measures such as macromolecular pool fraction [12]. In this work, we analyze the effect of NE component on qMT and MTR parameters and provide results of numerical, phantom and in-vivo validation of the approach as a way to minimize underestimation of qMT measures due to PVE. Additionally, we developed a fast-optimized protocol for in-vivo application of NE-mCRI. METHODS: NE-mCRI is built on modified cross-relaxation imaging (mCRI) method [4,13], which estimates the standard two-pool MT model parameters such as bound pool fraction f, cross-relaxation rate k, and T2 of the bound pool T2 and parameters of the third pool associated with NE compartment. The estimation is performed by fitting the corresponding model to several SPGR datasets and MTweighted SPGR datasets sensitive to both MT and NE subsystems of the model. Simulation: To estimate errors in the qMT parameters and MTR caused by PVE, synthetic VFA and MT SPGR signal intensities were generated using the three-pool model for GM (R1 =0.71s ; f =8.8%; k=1.57s; T2=10.21μs) with the pulse sequence parameters of the in vivo study. The signals were then fit by the two-pool mCRI model. Additional numerical simulations were used to compare the accuracy in fitting 2-pool (mCRI) and 3-pool (NE-mCRI) models over the range of experimental conditions. Theoretical data were generated using the 3-pool model [11] for the range of brain bound pool fraction f (%)=(2,4,6,8,10,12,14,16,18, and 20) in the presence of different amount of NEf (%)=(0,5, 10,15,20,25,30,35,40,45, and 50). This provided a 10×11 bound pool fraction vs. non-exchanging fraction grid. For each simulation, 10,000 signals were generated from theoretical data with Gaussian-distributed additive noise. The parameters of each model were estimated by fitting the synthetic data to both 2-pool and 3-pool models. Phantom and Healthy Volunteer Experiments: All data were acquired on a 3.0T GE MR750 scanner. Flip angle (B1) and field (B0) maps were measured by AFI [14] and IDEAL [15]. 25% cylindrical shape gelatin phantom (covered by plastic wrap to prevent diffusion exchange) was placed in the water bath. The imaging plane was tilted in respect to the phantom to introduce PV from surrounding water varying along the phantom axis. SPGR and MT-SPGR data were acquired with the same TR/TE/image matrix (3D SPGR data: α=[3,7,19,40] ̊; MT VFA SPGR data with all combinations of (α=19 ̊,Δ=2.5,5,9,13kHz, αMT=[800,1300] ̊) and (α=[3,7,40] ̊,Δ=2.5,13kHz,αMT=[800,1300] ̊). The data at α=7 ̊, Δ=2.5kHz, αMT=1300 ̊ and corresponding SPGR data was used to calculate MTR. The optimized human protocol (Monte-Carlo simulations) includes three VFA SPGR (α=[4,14,26] ̊, TR/TE =23/2.0ms) and five MT VFA SPGR (Δ(kHz)/αMT/α = 2/1170 ̊/4 ̊, 2/1170 ̊/14 ̊,2/1170 ̊/26 ̊,2/600 ̊/14 ̊,8/1170 ̊/14 ̊) with TR/TE= 40/2.0ms. All Z-spectroscopic and VFA data were acquired with FOV=220×220×176mm and matrix=150×150×44. 4mm slice thickness was prescribed to introduce more PVE and better appreciate the correction by NE-mCRI method. RESULTS: Simulations: PVE with NE component progressively decreases apparent estimates of MTR and all parameters of 2-pool MT model with k and T2 being most and least affected, respectively (Fig.1). Fig. 2 shows the estimated bound pool fraction across the range of f and NEf values for both 2-pool and 3pool models. The standard 2-pool method increasingly underestimates the f as the NEf increases, while the 3-pool method correctly estimates the f for the range of NEf, which can be appreciated by the uniform bound pool fraction estimated for each f for the range of NEf (across each column). Phantom Studies: The NE water fraction estimated by NE-mCRI (3-pool) increases along the tilted phantom. These changes are accompanied by a decrease in MTR and f estimated by standard two-pool model mCRI. NE-mCRI estimate of f shows much less variability along the phantom reflecting uniform composition of MT phantom rather than macroscopic partial volume with surrounding water. In Vivo: Fig. 4 illustrates effect of CSF PVE modeling on qMT parameters using 2-pool model and its correction by the 3-pool model. The removal of partial volume effect by CSF markedly increases the apparent size of GM structures on f map in the areas with PVE from CSF (bordering the ventricles, red arrows in Fig. 4). Difference maps between two models parameters better show the correction using 3-pool model on PV region, which are consistent with the simulation results (Fig.1) showing highest error in k and lowest error in T2. Model preference is quantified by both residual maps comparison (showing higher residuals with 2-pool model especially in PVE with CSF) and Bayesian information criterion (BIC) map showing 3-pool is preferred for the majority of brain voxels. DISCUSSION: This work establishes feasibility of estimating the third pool (NE component) in addition to the standard two-pool qMT parameters from a set of MT-weighted SPGR data. Our results indicate that such estimation can be performed quite robustly for the range of f values for both normal and demyelinated tissues (Fig. 2). As GMCSF PVE may be significant at typical resolutions of qMRI techniques [9,10], CSF may be a serious confounder for MT-based characterization of GM myelination using either MTR or f potentially affecting voxel-wise and histogram analyses (Fig. 1). Our results demonstrate that explicit modeling of PVE using our NE-mCRI approach efficiently corrects CSF PVE biases in qMTI (Figs. 3,4). It was noted before that increasing CSF PVE with developing brain atrophy in the course of MS disease reduces apparent values of MT contrast histogram [16]. Such effect inevitably reduces specificity of MTI to myelination, making it sensitive to both demyelination and atrophy. Removal of PVE from qMT measurements may improve characterization of myelin status in cortical GM especially in subpial regions. Bound Pool Fraction (%)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pathological Assessment of Brain White Matter in Relapsing-Remitting MS Patients using Quantitative Magnetization Transfer Imaging

Introduction: Multiple sclerosis (MS) is characterized by lesions in the white matter (WM) of the central nervous system. Magnetic resonance imaging is the most specific and sensitive method for diagnosis of multiple sclerosis. However, the ability of conventional MRI to show histopathologic heterogeneity of MS lesions is insufficient. Quantitative magnetization transfer imaging (qMTI) is a rel...

متن کامل

A Novel Classification Method using Effective Neural Network and Quantitative Magnetization Transfer Imaging of Brain White Matter in Relapsing Remitting Multiple Sclerosis

Background: Quantitative Magnetization Transfer Imaging (QMTI) is often used to quantify the myelin content in multiple sclerosis (MS) lesions and normal appearing brain tissues. Also, automated classifiers such as artificial neural networks (ANNs) can significantly improve the identification and classification processes of MS clinical datasets.Objective: We classified patients with relapsing-r...

متن کامل

The Assessment of Structural Changes in MS Plaques and Normal Appearing White Matter Using Quantitative Magnetization Transfer Imaging (MTI)

Introduction: Multiple sclerosis (MS) is a demyelinating disease of the central nervous system (CNS), affecting mostly young people at a mean age of 30 years. Magnetic resonance imaging (MRI) is one of the most specific and sensitive methods in diagnosing and detecting the evolution of multiple sclerosis disease. But it does not have the ability to differentiate between distinct histopathologic...

متن کامل

Analytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging

Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...

متن کامل

Multi objective optimization of the MED-TVC system with exergetic and heat transfer analysis

The mathematical model to predict the performance and the exergetic efficiency in a multi-effect desalination system with thermal vapor compression (MED-TVC system) has been presented. The energy and the concentration conservation law were developed for each effect, considering the boiling point elevation and the various thermodynamic losses by developing the mathematical models. These analyses...

متن کامل

Meshless analysis of casting process considering non-Fourier heat transfer

Casting is considered as a major manufacturing process. Thermal analysis of a solidifying medium is of great importance for appropriate design of casting processes. The conventional governing equation of a solidifying medium is based on the Fourier heat conduction law, which does not account for the phase-lag between the heat flux and the temperature gradient. In this paper, the concept of phas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013