Assessing the depth of dexmedetomidine-induced sedation with electroencephalogram (EEG)-based spectral entropy.

نویسندگان

  • A Maksimow
  • A Snapir
  • M Särkelä
  • E Kentala
  • J Koskenvuo
  • J Posti
  • S K Jääskeläinen
  • S Hinkka-Yli-Salomäki
  • M Scheinin
  • H Scheinin
چکیده

BACKGROUND Adequate sedation of critically ill patients improves the outcome of intensive care. Maintaining an optimal level of sedation in the intensive care unit (ICU) is difficult because of a lack of appropriate monitoring methods to guide drug dosing. Dexmedetomidine, a selective alpha(2)-adrenoceptor agonist, has recently been introduced for the sedation of ICU patients. This study investigated the utility of electroencephalogram (EEG)-based spectral entropy monitoring (with M-ENTROPY, GE Healthcare, Helsinki, Finland) for the assessment of dexmedetomidine-induced sedation. METHODS Eleven healthy, non-smoking men, aged 23.9 +/- 2.5 years (mean +/- standard deviation), were recruited. Spectral entropy was recorded before and during low (0.5 ng/ml) and high (5 ng/ml) plasma concentrations of dexmedetomidine. At the end of the infusion, subjects were awakened by verbal command and light shaking. RESULTS Spectral entropy decreased from 84 +/- 5 to 66 +/- 16 (P= 0.029) during low dexmedetomidine levels and from 84 +/- 5 to 20 +/- 12 (P < 0.001) during high dexmedetomidine levels. Transitions during loss and regaining of consciousness were analysed separately. Entropy decreased from 76 +/- 8 before to 43 +/- 10 (P < 0.001) after loss of consciousness, and increased from 14 +/- 4 to 63 +/- 13 (P < 0.001) on regaining of consciousness. These changes were consistent across all subjects. Prediction probability and sensitivity values indicated a high predictive performance of the method. CONCLUSION The depth of dexmedetomidine-induced sedation can be monitored with EEG-based spectral entropy. These results should be confirmed in a clinical setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

BIS and spectral entropy monitoring during sedation with midazolam/remifentanil and dexmedetomidine/remifentanil

Haenggi and colleagues report considerable intra- and inter-individual variability in derived electroencephalogram (EEG) parameters (Bispectral Index (BIS), response entropy and state entropy) recorded in volunteers sedated with midazolam or dexmedetomidine infusions titrated to modified Ramsay scores of 2, 3 and 4, and a remifentanil infusion at a fixed target concentration. Possible explanati...

متن کامل

Intra- and inter-individual variation of BIS-index® and Entropy® during controlled sedation with midazolam/remifentanil and dexmedetomidine/remifentanil in healthy volunteers: an interventional study

INTRODUCTION We studied intra-individual and inter-individual variability of two online sedation monitors, BIS and Entropy, in volunteers under sedation. METHODS Ten healthy volunteers were sedated in a stepwise manner with doses of either midazolam and remifentanil or dexmedetomidine and remifentanil. One week later the procedure was repeated with the remaining drug combination. The doses we...

متن کامل

Assessment of Anesthesia Depth Using Effective Brain Connectivity Based on Transfer Entropy on EEG Signal

Introduction: Ensuring an adequate Depth of Anesthesia (DOA) during surgery is essential for anesthesiologists. Since the effect of anesthetic drugs is on the central nervous system, brain signals such as Electroencephalogram (EEG) can be used for DOA estimation. Anesthesia can interfere among brain regions, so the relationship among different areas can be a key factor in the anesthetic process...

متن کامل

Behavior of entropy/complexity measures of the electroencephalogram during propofol-induced sedation: dose-dependent effects of remifentanil.

BACKGROUND Several new measures based on the regularity of the electroencephalogram signal for the assessment of depth of anesthesia/sedation have been proposed recently. In this study we analyze the influence of remifentanil and electroencephalogram frequency content of the performance of a set of such measures. METHODS Forty-five patients with American Society of Anesthesiologists physical ...

متن کامل

Dexmedetomidine is effective for sedation for outpatient elec- troencephalography

Background Ideally an electroencephalogram (EEG) should be obtained when the patient is in their baseline, non-sedated state. However, this can be challenging in children, especially those with autism. We reviewed our experience utilizing dexmedetomidine for sedation for EEG, in particular, younger children and those with autism. Methods A retrospective cohort study was performed on all patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta anaesthesiologica Scandinavica

دوره 51 1  شماره 

صفحات  -

تاریخ انتشار 2007