NICMOS Two Gyro Mode Coronagraphic Performance

نویسنده

  • G. Schneider
چکیده

In preparation for the Hubble Space Telescope (HST) entry into Two Gyro Mode (TGM) operations, the NICMOS coronagraphic performance was assessed during the February 21, 2005 TGM on orbit test (ID: 10448) in two filter bands (F110W and F160W). The gyroscope pair 2-4 was used for the TGM test. Observations were obtained of a previously observed calibration target (GJ517; sp.type=K5Ve) coronagraphically and with direct imaging. The F110W filter performance very closely tracks the three gyro mode (ID: 10177) results. The observed jitter of ~6.2 mas had little effect on the 1.1 μm coronagraphy. This result clearly shows that 1.1 μm coronagraphy is robust against the observed TGM jitter. The NICMOS coronagraph inner working angle (IWA) is 3.2 λ/D at 1.1 μm. Consequently, there is sufficient performance compliance to target decentering of these RMS amplitudes within the coronagraphic hole. There was a slight decline in performance with the F160W filter with respect to three gyro mode which may be due to imaging systematics; i.e., breathing and jitter. The 1.6 μm coronagraphy is more susceptible to imaging systematics primarily due its broader PSF (IWA=2.2 λ/D). At r=10 pixels, the coronagraphic diffracted and scattered light suppression factor is ~3 compared to direct imaging, while it is a factor of 4 in three gyro mode. The observed coronagraphic performance is essentially unaffected at 1.1 μm with TGM operations, while there is a marginal decline at 1.6 μm of similar amplitude to that arising from other well-known HST/NICMOS orbit-driven instabilities. The improvement in image contrast (and dynamic range) with coronagraphy and TGM is still substantial over direct imaging. Copyright© 1999 The Association of Universities for Research in Astronomy, Inc. All Rights Reserved. Instrument Science Report NICMOS 2005-00

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polarimetry with NICMOS

NICMOS cameras 1 and 2 (with ∼ 43 and ∼ 76 mas/pixel, respectively) each carry a set of three polarizing elements to provide high sensitivity observations of linearly polarized light. The polarizers are bandpass limited and provide diffraction-limited imaging in camera 1 at 0.8 1.3μm, and in camera 2 at 1.9-2.1μm. The NICMOS design specified the intra-camera primary axis angles of the polarizer...

متن کامل

NICMOS Coronagraphy: Recalibration and the NICMOS Legacy Archive PSF Library

NICMOS coronagraphy, with well-matched template Point Spread Function (PSF) subtraction, probes the closest environments of occulted targets with the highest imaging sensitivity in intrinsically high contrast fields at the smallest radial distances afforded, uniquely, by HST. NICMOS PSF-subtracted coronagraphy has been invoked in a wide variety of HST programs with science themes as divergent a...

متن کامل

Coronagraphy with NICMOS

The Near Infrared Camera and Multi-Object Spectrometer (NICMOS) provides a coronagraphic imaging capability in camera 2. NICMOS PSF-subtracted coronagraphy routinely results in per-pixel background rejections of ∼ 10 of an occulted target’s total flux density at an angular distance of 1′′, thus providing a highcontrast lever for the detection of close sub-stellar companions. At 1.1 μm (with an ...

متن کامل

Guiding Errors in 3-Gyro: Experience from WF/PC, WFPC2, STIS, NICMOS and ACS

As background information to support interpretation of results during testing under 2-gyro operation, this report summarizes typical behavior gleaned from several observations with ACS, WF/PC, WFPC2, STIS and NICMOS. The observations used have all been for at least five consecutive orbits, and have collected data with the goal of producing very high signal-to-noise, time-series photometry for w...

متن کامل

Long-term trends in the NICMOS Camera 2 obscuration pattern and aberrations

Phase retrieval measurements of well-exposed NICMOS Camera 2 star images show that long-term changes occurred in coma and the cold mask position over the 1997-1998 lifespan of the instrument. These caused time-dependent variations in the PSF diffraction pattern, notably the shape of the Airy rings and the positions of bands in the diffraction spikes. These effects are evident in both direct and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005