Noninvasive MRI of tissue redox state based on endogenous chemical exchange saturation transfer (CEST) contrast

نویسندگان

  • Kejia Cai
  • He N Xu
  • Anup Singh
  • Lily Moon
  • Mohammad Haris
  • Xiaohong Joe Zhou
  • Ravinder Reddy
  • Lin Z Li
چکیده

Target audience: Research scientists or clinicians who are interested in cancer metabolism, oxidative stress and redox state. Introduction/Purpose: Cellular redox state has been demonstrated as a key player in cellular biology. The disturbed balance of the redox state, such as excessive oxidative stress, can lead to many pathologic changes including cancer, heart diseases, neurodegenerative diseases, and diabetes. Imaging biomarkers for oxidative stress are a key research area. Tumor redox state heterogeneity revealed by the optical redox scanning of ex vivo tissues may differentiate tumor aggressiveness. However, the redox scanning is highly invasive, limiting its use. The purpose of this study is to develop a non-invasive MR imaging method for mapping the tissue redox state based on the endogenous Chemical Exchange Saturation Transfer (CEST) contrast. We report herein a CEST MRI technique, together with correlations to the optical redox scanning to characterize tumor redox heterogeneity. The mechanism on such correlation has also been investigated. Methods: All animal experiments on two human breast cancer mouse xenograft models, MDA-MB-231 (n=8) and MCF-7 (n=6), were performed according to an Institutional Animal Care and Use Committee approved protocol. The tumors were grown as previously described and the tumor volumes ranged from 100 mm to 1000 mm. CEST Z-spectra images of the tumor central slice with saturation offsets from -5 to 5 ppm and a step-size of 0.25 ppm were collected on a 9.4T Varian small animal MR scanner using a customized sequence, which consists of a frequency selective rectangular saturation pulse (B1=250 Hz, 1 s) followed by a segmented Fast Low-Angle SHot (FLASH) readout. Both B0 and B1 field inhomogeneity maps were acquired for the correction of CEST contrast maps from +2 to +4 ppm, normalized to the corresponding negative saturation offsets as previously reported. In addition, magnetization transfer (MT) images, T1and T2-weighted images of the same slice were also acquired. After MRI, the tumor-bearing mice under anesthesia underwent snap-freezing procedures and the excised frozen tumors were embedded for multi-slice fluorescence imaging of NADH (reduced form of nicotinamide adenine dinucleotide) and Fp (oxidized flavoproteins) using the Chance redox scanner to quantify the NADH redox ratio, NADH/(Fp+NADH). We then performed CEST MRI of the solutions of the major metabolites (see Figure 3) in two redox reactions, representative of many others in vivo in a general form of RH2 + NAD + ↔ R + NADH + H, where R is the substrate. As NAD and NADH concentrations are <1 mM in vivo and the additional proton (H) in NADH is associated with a carbon, their difference in CEST contrast is negligible. All solutions were freshly prepared in PBS at pH 7.0 and maintained at 37 C. Results: The multi-modality MRI study (Figure 1A-D) demonstrates that only CEST MRI showed distinctive core-rim patterns from the MDA-MB-231 tumors (rim to core ratio 1.54 ± 0.17) comparing to the MCF-7 tumors (1.21 ± 0.19, p<0.05). This rim to core separation appeared independent of the CEST saturation offset from +2 to +4 ppm (Figure 1E). CEST contrasts from individual tumor rim and core are linearly correlated with the NADH redox ratios quantified by the optical redox scanning (p=0.00002, Figure 2). Through the phantom studies on the metabolites in two representative redox reactions (Figure 3), we found that the reductants (in this case, glutamate and alanine) generally expressed a higher CEST contrast than the corresponding oxidants (oxoglutarate and pyruvate) due to the reception of mobile protons through the NAD(P)/NAD(P)H mediated redox reactions. This explains why higher tissue CEST contrast in vivo corresponded to more reduced redox state as shown in Figure 2B. Discussion: Our study demonstrates that CEST MRI is capable of revealing the tumor rim to core bimodal pattern, as observed by the optical redox scanning. The quantitative and significant correlation between the CEST MRI and the optical scanning indicates that the overall CEST contrast in vivo can be an imaging biomarker of the NADH redox ratio. This correlation is supported by the phantom studies on the metabolites of two redox reactions which are representative of many other redox reactions in vivo. Non-invasive CEST MRI of tissue redox state, as a new imaging marker, may find new clinical applications in diagnosis of cancer as well as other diseases. It is worth noting that the overall CEST contrast in vivo may also be affected by other factors, including tissue pH, T1 and T2, and the metabolites that are not involved in redox reactions. Hence, CEST MRI of tissue redox state requires calibration and the comparison may only be made between similar tissue types. Despite these limitations, this study demonstrates a novel MRI technique sensitive to tissue redox state. References: [1].Cook JA, et al. Oxidative stress, redox, and the tumor microenvironment. Seminars in Radiation Oncology. 2004;14:259-66. [2].Barnham KJ, et al. Nat Rev Drug Discov. 2004;3:205-14. [3].Allen RG, et al. Free Radic Biol Med. 2000;28:463-99. [4].Li LZ, et al. PNAS. 2009;106:6608-13. [5]. Xu HN, et al. Journal of biomedical optics. 2010;15:036010. [6].Cai K, et al. Nat Med. 2012;18:302-6. Figure 1. Images of the two breast cancer models: MDA-MB-231 (top) and MCF-7 (bottom) with multi-modality MRI: T1-weigthed (T1-w, A), T2-weigthed (T2-w, B), magnetization transfer ratio (MTR) (C) and CEST at 2ppm (D). T1, T2-weighted and MTR contrast does not exhibit a clear bimodal rim to core pattern in either of the tumor models. Only the CEST contrast exhibits clear rim to core separation from the MDA-MB-231 tumor. (E) Relationships between saturation offset and the rim-tocore ratio of the CEST contrast for the two breast cancer animal models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging

Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...

متن کامل

Fast multislice pH-weighted chemical exchange saturation transfer (CEST) MRI with Unevenly segmented RF irradiation.

Chemical exchange saturation transfer (CEST) MRI is a versatile imaging technique for measuring microenvironment properties via dilute CEST labile groups. Conventionally, CEST MRI is implemented with a long radiofrequency irradiation module, followed by fast image acquisition to obtain the steady state CEST contrast. Nevertheless, the sensitivity, scan time, and spatial coverage of the conventi...

متن کامل

Cardio-chemical exchange saturation transfer magnetic resonance imaging reveals molecular signatures of endogenous fibrosis and exogenous contrast media.

BACKGROUND Application of emerging molecular MRI techniques, including chemical exchange saturation transfer (CEST)-MRI, to cardiac imaging is desirable; however, conventional methods are poorly suited for cardiac imaging, particularly in small animals with rapid heart rates. We developed a CEST-encoded steady state and retrospectively gated cardiac cine imaging sequence in which the presence o...

متن کامل

A theoretical analysis of chemical exchange saturation transfer echo planar imaging (CEST-EPI) steady state solution and the CEST sensitivity efficiency-based optimization approach.

Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute labile protons and microenvironmental properties, augmenting routine relaxation-based MRI. Recent developments of quantitative CEST (qCEST) analysis such as omega plots and RF-power based ratiometric calculation have extended our ability to elucidate the underlying CEST system beyond the simplistic apparent CEST measurement...

متن کامل

A novel class of polymeric pH-responsive MRI CEST agents.

In this communication, we report that ionizable, tertiary amine-based block copolymers can be used as pH-responsive contrast agents for magnetic resonance imaging (MRI) through the chemical exchange saturation transfer (CEST) mechanism. The CEST signal is essentially "off" when the polymers form micelles near physiological pH but is activated to the "on" state when the micelles dissociate in an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013