Method to plan, administer, and verify supine craniospinal irradiation
نویسندگان
چکیده
Craniospinal irradiation remains an important technique in the management of malignancies of the central nervous system. It is technically demanding, with potential for treatment field overlap or gaps to yield unacceptable dosimetric heterogeneity. A method to accurately simulate and verify the three-field junction is described. We use a comfortable supine position to minimize patient movement. The supine position provides airway access by anesthesiology in patients requiring sedation or anesthesia. Virtual simulation is performed with a dedicated computed tomography (CT) simulator. Multiplanar sagittal and coronal CT reconstructions allow visual confirmation of three-field matching at the cervical region. The placement of isocenters for each field, table position, and collimator angles are determined by calculation of field sizes accommodating for beam divergence. At treatment, exact matching of the three fields is assured using the record and verify confirmation of beam collimator settings and rotation, digital couch readouts, and gantry parameters. Mini-verification silver halide (Kodak XV) films (6x6 cm) are placed behind the patient's neck and are exposed by all treatment fields (posterior flash from the lateral cranial fields and entrance from the PA spine field). These films assess field placement accuracy at the junction of these three fields. Finally, placement of radio-opaque markers at the junction is visualized in each clinical portal radiograph. Patients readily accept the supine position as their treatment setup is eased. Field placement using digital couch settings is efficient and accurate. Daily mini-verification films are simple, inexpensive, and allow verification of each treatment field matching. Field placement errors of greater than 1 mm can be readily identified and corrected at subsequent treatment sessions. Virtual simulation and direct junction verification with mini-verification films allow for simple and quantitative evaluation of the junction associated with the three-field craniospinal irradiation technique. The supine patient position does not present any difficulties in field matching or verification.
منابع مشابه
A feasibility study using TomoDirect for craniospinal irradiation
The feasibility of delivering craniospinal irradiation (CSI) with TomoDirect is investigated. A method is proposed to generate TomoDirect plans using standard three-dimensional (3D) beam arrangements on Tomotherapy with junctioning of these fields to minimize hot or cold spots at the cranial/spinal junction. These plans are evaluated and compared to a helical Tomotherapy and a three-dimensional...
متن کاملCraniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique
Background: Craniospinal irradiation (CSI) of medulloblastoma poses technological challenges due to the involvement of large treatment volume. Commonly, the whole treatment length is covered with two different isocentric plans in which the junction is shifted after every five fractions to overcome the possibility of hot and cold spot.Objective: This study aims to evaluate dosimetrically and cli...
متن کاملClinical Implementation of Robust Optimization for Craniospinal Irradiation
With robust optimization for spot scanning proton therapy now commercially available, the ability exists to account for setup, range, and interfield uncertainties during optimization. Robust optimization is particularly beneficial for craniospinal irradiation (CSI) where the large target volume lends itself to larger setup uncertainties and the need for robust match lines can all be handled wit...
متن کاملAn image‐guided technique for planning and verification of supine craniospinal irradiation
We present a technique for planning and verification of craniospinal treatment with the patient in the supine position. Treatment delivery and verification is streamlined through the use of modern imaging techniques. Treatments use two lateral brain fields abutted to a single or pair of posterior spine fields. Treatment delivery is simplified by aligning all isocenters in the anterior-posterior...
متن کاملA simple technique for craniospinal radiotherapy in the supine position.
PURPOSE Craniospinal irradiation poses technical difficulties that may be addressed with the use of the newer technologies that have become available over the past decade. The use of CT simulation allows improved target localisation and beam geometry definition while significantly reducing the treatment simulation time. We have developed a CT-based technique for whole CNS irradiation in the sup...