Fransthoracic Ventricular Defibrillatlon with Square-wave Stimuli: ONE-HALF CYCLE,

نویسندگان

  • John C. Schuder
  • Harry Stoeckle
  • Alfred M. Dolan
چکیده

• In 1960 Kouwenhoven, Jude, and Knickerbocker reported that adequate circulation of the blood could be achieved by means of closed chest cardiac massage. This technique is said to permit the oxygen demands of the myocardium to be satisfied by external means and thereby makes practical the utihzation of transthoracic electric shock for the reversal of ventricular fibrillation. However, Del Guerico et al.,have observed low cardiac output in three patients undergoing external cardiac massage. Alexander et al. reported successful treatment of ventricular tachycardia by transthoracic electric shock in 1961. Their paper was followed by others, particularly from Lown's group *~° which described the successful use of transthoracic shock for terminating a variety of other cardiac arrhythmias. As a result of both these developments, the use of electric shocks applied by means of electrodes held on the surface of the chest has assumed an appreciably increased clinical importance in the treatment of cardiac arrhythmias. With this increased importance and use has come a renewal of interest in evaluating the effectiveness of different types of electric shocks in order to find the most satisfactory waveform. This interest has led to the development of several types of external defibrillators which deliver capacitor discharges.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship of ventricular excitability characteristics to ventricular arrhythmias in dogs.

The relationship of the form of ventricular anodal strength-interval curves to the types of arrhythmias induced by trains of low-intensity stimuli was studied in 16 dogs. Strength-interval curves were determined after basic atrial driven beats and after induced premature ventricular depolarizations. The test stimuli for these determinations were 2-msec anodal square waves delivered in 1-msec de...

متن کامل

Full-wave and half-wave rectification in second-order motion perception.

UNLABELLED Microbalanced stimuli are dynamic displays which do not stimulate motion mechanisms that apply standard (Fourier-energy or autocorrelational) motion analysis directly to the visual signal. In order to extract motion information from microbalanced stimuli, Chubb and Sperling [(1988) Journal of the Optical Society of America, 5, 1986-2006] proposed that the human visual system performs...

متن کامل

Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography

Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...

متن کامل

Normal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran

The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...

متن کامل

Post-photoreceptoral activity dominates primate photopic 32-Hz ERG for sine-, square-, and pulsed stimuli.

PURPOSE To evaluate the relative contributions of photoreceptors and postphotoreceptoral activity to the primate 32-Hz flicker electroretinogram (ERG) elicited by sine-wave, square-wave, and pulse stimuli. METHODS Flicker 32-Hz ERGs were evoked from four adult rhesus (Macaca mulatta) monkeys using sine-wave, square-wave, and 4-ms pulse trains and xenon photostrobe flicker stimuli. All stimuli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005