Results by fluorescent immunoassay for phenytoin compared with those by enzyme immunoassay, liquid chromatography, and discrete analysis (Dupont aca).
نویسندگان
چکیده
We describe the Ames Fluorescent Enzyme Immunoassay procedure for the detection of phenytoin in serum, and compare the results with it with those by enzyme immunoassay(EMIT), "high-pressure" liquid chromatography, and the Dupont aca. Sera from 48 patients who were receiving phenytoin were promptly analyzed in duplicate by EMIT, frozen, then assayed within four weeks by the other three methods. Correlation was good between results by the fluorescent immunoassay and the other methods. The fluorescent immunoassay procedure is sensitive and requires a small sample volume (100 microliters). Sample reading time can be shortened from 30 to 15 s as the technician becomes more proficient, with no sacrifice of accuracy. The procedure is fast, easy to perform, specific, sensitive, and inexpensive; involves no radioactivity; and requires no temperature control. It is the current method of choice for detection of phenytoin in serum, in terms of precision and accuracy.
منابع مشابه
Comparative determination of phenytoin by spectrophotometry, gas chromatography, liquid chromatography, enzyme immunoassay, and radioimmunoassay.
Sera from patients being treated with phenytoin were analyzed for the drug by spectrophotometry, gas chromatography, radioimmunoassay, enzyme immunoassay, and liquid chromatography. The essay values obtained were intercompared statistically. Enzyme immunoassay and liquid chromatography appear to be attractive alternatives to the more traditional methods of spectrophotometry and gas chromatograp...
متن کاملSubstrate-labeled fluorescent immunoassay for phenytoin in human serum.
A homogeneous substrate-labeled fluorescent immunoassay has been applied to the measurement of phenytoin concentrations in human serum. We coupled a fluorogenic enzyme substrate, galactosyl-umbelliferone, covalently to a derivative of phenytoin. Under assay conditions, this drug-substrate conjugate was nonfluorescent but became fluorescent upon hydrolysis catalyzed by bacterial beta-galactosida...
متن کاملFalsely increased immunoassay measurements of total and unbound phenytoin in critically ill uremic patients receiving fosphenytoin.
BACKGROUND Fosphenytoin, a phosphate ester prodrug of phenytoin, is metabolized to phenytoin in vivo. Phenytoin metabolites accumulate in renal insufficiency and cross-react in some phenytoin immunoassays. Our aim was to determine the accuracy of phenytoin immunoassays in renal patients treated with fosphenytoin. METHODS We measured phenytoin with HPLC and with the aca, ACS:180, TDx phenytoin...
متن کاملEnzymatic immunoassay vs. gas/liquid chromatography for determination of phenobarbital and diphenylhydantoin in serum.
The antiepileptic drugs diphenylhydantoin and phenobarbital were measured in serum by a new commercially available enzyme immunoassay procedure ("EMIT," Syva Corp.). The procedure requires less than 5 min and no more than 50 mul of serum per determination. It is simple; only four steps (pipetting and diluting with an automatic pipettor-dilutor) are required before spectrophotometry. Twenty repl...
متن کاملHomogeneous fluorescent immunoassay with dry reagents.
We described an assay for theophylline in serum in which the reagents for the substrate-labeled fluorescent immunoassay procedure are dry reagents in a paper matrix. This assay format is both rapid and convenient. In one such paper strip assay, the competing drug conjugate is present in the diluting buffer (dilution-into-conjugate strip assay); in another, all necessary assay reagents are conta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 28 7 شماره
صفحات -
تاریخ انتشار 1982