Simulation-based evaluation of OSEM iterative reconstruction methods in dynamic brain PET studies
نویسندگان
چکیده
The reconstruction of dynamic PET data is usually performed using filtered backprojection algorithms (FBP). This method is fast, robust, linear and yields reliable quantitative results. However, the use of FBP for low count data, such as dynamic PET data, generally results in poor visual image quality, exhibiting high noise, disturbing streak artifacts and low contrast. These signal-to-noise ratio and contrast in the reconstructed images may alter the quantification of physiological indexes, such as the regional Binding Potential (BP) obtained from kinetic modeling. Iterative reconstruction methods are often presented as viable alternatives to FBP reconstruction. In this study, we investigated the characteristics of the UW-OSEM and the ANW-OSEM iterative reconstruction methods in the context of ligand-receptor PET studies with low counts. The assessment was conducted using replicates of simulated [18F]MPPF acquisitions. The quantitative accuracy obtained with the iterative and analytical methods was compared. The results show that analytical methods are more robust to the low count data than iterative methods, and therefore enable a better estimate of the regional activity values and binding potential. The positivity constraint in MLEM-based algorithms leads to overestimations of the activity in regions with low activity concentration, typically the cerebellum. This overestimation results in significant bias in BP estimates with iterative reconstruction methods. The bias is confirmed from the reconstruction of real PET data.
منابع مشابه
Accuracy of 3-dimensional reconstruction algorithms for the high-resolution research tomograph.
UNLABELLED The high-resolution research tomograph (HRRT) is a dedicated human brain PET scanner. At present, iterative reconstruction methods are preferred for reconstructing HRRT studies. However, these iterative reconstruction algorithms show bias in short-duration frames. New algorithms such as the shifted Poisson ordered-subsets expectation maximization (SP-OSEM) and ordered-subsets weighte...
متن کاملEvaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom
Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...
متن کاملLOR-OSEM: Statistical PET Reconstruction from Raw LOR Histograms
Iterative statistical reconstruction methods are becoming the standard in positron emission tomography (PET). Conventional maximum-likelihood expectation-maximization (MLEM) and ordered-subsets (OSEM) algorithms act on data which has been pre-processed into corrected, evenly-spaced histograms; however, such pre-processing corrupts the Poisson statistics. Recent advances have incorporated attenu...
متن کاملExperimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: quantitative characteristics and effects on kinetic modeling.
UNLABELLED The purpose of this study was to investigate the quantitative properties and effects of ordered-subset expectation maximization (OSEM) on kinetic modeling compared with filtered backprojection (FBP) in dynamic PET studies. Both phantom and patient studies were performed. METHODS For phantom studies dynamic two-dimensional emission scans with 10-min frames and 20-min scan intervals ...
متن کامل[Quantitative evaluation of block-iterative reconstruction image in PET: comparison of the dynamic RAMLA algorithm and OSEM algorithm].
PURPOSE Iterative reconstruction has been successfully used in whole-body PET imaging because of reductions in noise and scanning time. However, there are plural algorithms for image reconstruction such as OSEM, RAMLA and Dynamic RAMLA. Dynamic RAMLA (DRAMA) is an iterative algorithm similar to RAMLA, but the relaxation parameter is controlled in such a way that the propagation of noise from pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 39 1 شماره
صفحات -
تاریخ انتشار 2008