Glucose oxidase entrapped in polypyrrole on high-surface-area Pt electrodes: a model platform for sensitive electroenzymatic biosensors

نویسندگان

  • Jianjun Wang
  • Nosang V. Myung
  • Minhee Yun
  • Harold G. Monbouquette
چکیده

Enzyme entrapped in an electrosynthesized polymer film on a high-surface-area electrode is shown to be an attractive platform for the important class of amperometric biosensors based on oxidases and electrooxidation of the H2O2 generated by enzyme-catalyzed oxidation of analyte. Two Pt electrode surface morphologies, Pt black (Pt-BLK) and Pt nanowire brush (Pt-NW) were electrodeposited from chloroplatinic acid. Glucose oxidase (GOx) served as the model enzyme, which was entrapped in an electropolymerized polypyrrole (PPY) film on the high-surface-area Pt electrodes. The glucose sensitivity of the GOx electrodes can be controlled simply through Pt deposition conditions and varies roughly linearly with electrode microscopic roughness factor. A sensitivity of 103 lA mM 1 cm 2 was achieved with the Pt-BLK/PPY-immobilized GOx system at an underlying electrode surface roughness of 318, which is 150-fold higher than the sensitivity of a bare evaporated Pt/PPY-immobilized GOx electrode with a surface roughness of 2–3. The apparent Michaelis constant for PPY-immobilized GOx ( 30 mM) is similar to that for free enzyme (25 mM) suggesting that the overall electrode kinetics are not limited by glucose mass transfer. Scanning electron micrographs of enzyme electrode surfaces and a fluorescence assay to determine immobilized GOx concentration revealed that the PPY-GOx layer is deposited as a thin film that follows the contours of the electrode surface and that up to 3-fold greater enzyme is entrapped on the roughest electrodes examined. The orders of magnitude greater sensitivity of enzyme electrodes based on high-surface-area Pt appears likely to be due to increased H2O2 electrooxidation efficiency. 2004 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Inkjet Printing of Reducible AgNPs amperometric glucose biosensor Electrodes

The enzymes immobilization of the is crucially effective factor in biosensor preparation. Metal nanoparticles potentially able to immobilize the enzymes according to unique properties including large surface-to-volume ratio, high surface reaction activity, high catalytic efficiency, and strong adsorption ability. A novel and highly sensitive amperometric glucose biosensor was obtained by using ...

متن کامل

Fabrication and Optimization of a 25μm Glucose Sensor

Microelectrodes have been used for over 30 years of glucose biosensor history. Two different types of glucose biosensors were developed using 176μm and 25μm diameter Pt wire cylindrical microelectrodes. The 176 μm Pt wire type microelectrodes were modified with non-conductive polymers and glucose oxidase enzyme. The lifetime of biosensors was over 50 days and had negligible response to interfer...

متن کامل

Screen-printed microsystems for the ultrasensitive electrochemical detection of alkaline phosphatase.

Screen printing technique has been used to manufacture a microsystem where the graphite-based electrodes hold both a functional and an architectural task. The thick film manufacturing technique has proved valid to develop a very low volume (ca. 20 microL) device where different electrochemical operations can be very efficiently performed. Biomolecule immobilisation within the microsystem for bi...

متن کامل

Fast synthesis of platinum nanopetals and nanospheres for highly-sensitive non-enzymatic detection of glucose and selective sensing of ions

Novel methods to obtain Pt nanostructured electrodes have raised particular interest due to their high performance in electrochemistry. Several nanostructuration methods proposed in the literature use costly and bulky equipment or are time-consuming due to the numerous steps they involve. Here, Pt nanostructures were produced for the first time by one-step template-free electrodeposition on Pt ...

متن کامل

Highly sensitive glucose sensors based on enzyme-modified whole-graphene solution-gated transistors

Noninvasive glucose detections are convenient techniques for the diagnosis of diabetes mellitus, which require high performance glucose sensors. However, conventional electrochemical glucose sensors are not sensitive enough for these applications. Here, highly sensitive glucose sensors are successfully realized based on whole-graphene solution-gated transistors with the graphene gate electrodes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004