Development of a simulator for radiographic image optimization
نویسندگان
چکیده
A software package, incorporating two computational patient phantoms, has been developed for optimizing X-ray radiographic imaging. A tomographic phantom, visible photographic Man tomographic phantom (VIP-Man), constructed from Visible Human anatomical color images is used to simulate the scattered portion of an X-ray system using the Electron Gamma Shower National Research Council (EGSnrc) Monte Carlo code. The primary portion of an X-ray image is simulated using the projection ray-tracing method through the Visible Human CT data set. To produce a realistic image, the software simulates quantum noise, blurring effects, lesions, detector absorption efficiency, and other imaging artifacts. The primary and scattered portions of an X-ray chest image are combined to form a final image for future observer studies and image quality analysis. Absorbed doses in organs and tissues of the segmented VIP-Man phantom were also obtained from the Monte Carlo simulations. This paper presents methods of the simulator and preliminary results.
منابع مشابه
A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography
Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...
متن کاملOptimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations
IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...
متن کاملEvaluation of the Influence of Exposure Index on Image Quality and Radiation Dose
Introduction: The introduction of digital radiography has led to a significant problem in terms of dose creep. To address this problem, manufacturers have established a set of exposure indicators (EI) as a feedback mechanism to safeguard against overexposure. The EI is the measure of incident exposure to the detector that is directly proportional to the signal-to-noise...
متن کاملOptimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)
Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether in...
متن کاملبررسی میزان کیفیت تصاویر رادیوگرافی در بیمارستان های ارجاعی دولتی شهرستان ساری در سال 96
Background and purpose: Image quality together with low patient dose is two important goals in radiography procedures. Acquire radiographic images with inadequate quality give rise to uselessly patient dose, improper diagnosis, waste the cost and impose the biological effect to the patients. In this study image quality was evaluated for most common radiographic procedures based on indentified i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computer methods and programs in biomedicine
دوره 78 3 شماره
صفحات -
تاریخ انتشار 2005