Transient Behaviour of Conventional Current Transformers used as Primary Transducers and Input Elements in Protection IEDs and Stand Alone Merging Units

ثبت نشده
چکیده

Different types of CTs have different transient behaviour. Conventional CTs do not have the ability to continuously reproduce a DC component. However, the different types of CTs have more or less capability of reproducing the DC component for a limited time. Especially CTs with big airgaps have poor ability of reproducing DC components. Mixing this type of CT with other types of CTs for a differential protection can be a potential risk of unwanted operations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High gain multi-input DC-DC converter with combined phase-shift/PWM modulation for stand-alone applications

The existence of unreliable renewable energy resources would be required to use energy resources and storage units simultaneously, particularly in applications such as electrical vehicles and stand-alone energy supplying systems. The objective of this paper is to introduce a new topology of multi input converter in hybrid power supply system of photovoltaic, fuel cell and battery for medium pow...

متن کامل

معرفی روش تطبیقی اصلاح شده برای اندازه‌گیری دقیق ولتاژ در مبدل ولتاژ نوری

There are fewer problems encountered with optical voltage transducers in comparison with their inductive and capacitive counterparts. Although capacitive and inductive transformers are used vastly for the purpose of measurement and protection in the networks, they cause problems such as core saturation and improper transient responses which decrease the accuracy of measurement and eficiency of ...

متن کامل

Discrimination of Inrush from Fault Currents in Power Transformers Based on Equivalent Instantaneous Inductance Technique Coupled with Finite Element Method

The phenomenon of magnetizing inrush is a transient condition, which occurs primarily when a transformer is energized. The magnitude of inrush current may be as high as ten times or more times of transformer rated current that causes malfunction of protection system. So, for safe running of a transformer, it is necessary to distinguish inrush current from fault currents. In this paper, an equiv...

متن کامل

The Effect of Conventional Instrument Transformer Transients on Numerical Relay Elements

Current and voltage transducers provide instrument level signals to protective relays. Protective relay accuracy and performance are directly related to the steady state and transient performance of the instrument transformers. Protective relays are designed to operate in a shorter time than the time period of the transient disturbance during a system fault. Large instrument transformer transie...

متن کامل

transformer differential protection using the fault-generated high-frequency transient components

Power transformers are the most important components of a power system, so their protection is a critical issue. This paper proposes a novel and efficient algorithm based on the high-frequency components of the differential current signal to discriminate between the magnetizing inrush currents and the internal faults. After detecting the over-current in the differential current signals, samples...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013