BSA as additive: A simple strategy for practical applications of PNA in bioanalysis.

نویسندگان

  • Jieon Lee
  • Il-Soo Park
  • Henna Kim
  • Jae-Sung Woo
  • Byong-Seok Choi
  • Dal-Hee Min
چکیده

Application of peptide nucleic acid (PNA) in bioanalysis has been limited due to its nonspecific adsorption onto hydrophobic surface in spite of favorable properties such as higher chemical/biological stability, specificity and binding affinity towards target nucleic acids compared to natural nucleic acid probes. Herein, we employed BSA in PNA application to enhance the stability of PNA in hydrophobic containers and improve the sensing performance of the DNA sensor based on graphene oxide (GO) and PNA. Addition of 0.01% BSA in a PNA solution effectively prevented the adsorption of PNA on hydrophobic surface and increased the portion of the effective PNA strands for target binding without interfering duplex formation with a complementary target sequence. In the GO based biosensor using PNA, BSA interrupted the unfavorable adsorption of PNA/DNA duplex on GO surface, while allowing the adsorption of ssPNA, resulting in improvement of the performance of the DNA sensor system by reducing the detection limit by 90-folds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capacity Bounds and High-SNR Capacity of the Additive Exponential Noise Channel With Additive Exponential Interference

Communication in the presence of a priori known interference at the encoder has gained great interest because of its many practical applications. In this paper, additive exponential noise channel with additive exponential interference (AENC-AEI) known non-causally at the transmitter is introduced as a new variant of such communication scenarios‎. First, it is shown that the additive Gaussian ch...

متن کامل

BSA nanoparticles loaded with IONPs for biomedical applications: fabrication optimization, physicochemical characterization and biocompatibility evaluation

Objective(s): Cancer diagnosis in its early stages of progress, can enhance the efficiency of treatment utilizing conventional therapy methods. Non-biocompatibility of iron oxide nanoparticles (IONPs) has made a big challenge against their usage as a contrast agent. Efficient coverage by biomolecules such as albumin can be a solution to overcome this problem. Herein, albumin-coated IONPs were p...

متن کامل

Role of single-walled carbon nanotubes on ester hydrolysis and topography of electrospun bovine serum albumin/poly(vinyl alcohol) membranes.

Electrospun membranes were studied for the chemical deactivation of threat agents by means of enzymatic proteins. Protein loading and the surface chemistry of hybrid nanofibers influenced the efficacy by which embedded enzymes could digest the substrate of interest. Bovine serum albumin (BSA), selected as a model protein, was electrospun into biologically active fibers of poly(vinyl alcohol), P...

متن کامل

Synergistic effect of novel redox additives of p-nitroaniline and dimethylglyoxime for highly improving the supercapacitor performances.

In present work, we demonstrate a simple but effective strategy for high-performance supercapacitors by adding the p-nitroaniline (PNA) into an alkaline electrolyte of KOH. PNA possesses a unique molecular structure with the functional groups of -NH2 and -NO2. Besides, both the product of nitro-reduction (-NH2) and intrinsic -NH2 on the benzene ring can lead to the occurrence of Faradaic redox ...

متن کامل

Dual Space Control of a Deployable Cable Driven Robot: Wave Based Approach

Known for their lower costs and numerous applications, cable robots are an attractive research field in robotic community. However, considering the fact that they require an accurate installation procedure and calibration routine, they have not yet found their true place in real-world applications. This paper aims to propose a new controller strategy that requires no meticulous calibration and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 69  شماره 

صفحات  -

تاریخ انتشار 2015