PURPOSE There are two collimation systems associated with the CyberKnife system, the fixed cone collimator and the Iris collimator. The Iris collimator is used more frequently because of its superior flexibility. However, sometimes treatments have to be canceled or postponed due to Iris collimator mechanical failures. The purpose of this study is to investigate the feasibility of switching collimation systems without replanning. METHODS We first performed Monte Carlo simulations on 10 clinical cases using the Iris collimator and the fixed cone collimator. The conformality index (CI), target volume coverage and the maximum, minimum and mean doses to the critical structures from the iris and fixed plans were compared to determine the feasibility of switching between collimator types without replanning. RESULTS Our results showed that the two types of collimators deliver similar dose distributions. The average target doses for the fixed plans were 1% to 6% higher than those for the Iris plans. The average CI for the fixed plans was 1.36 compared to 1.28 for the Iris plans. Thus, we adjusted the Iris sizes with a scale factor of 1.024 to achieve a better dose match with the fixed collimators. Doses for the 10 cases were then recalculated. Once this correction was made, the difference between the average target doses for the two collimator plans was reduced to less than 2% and the CIs became almost identical. CONCLUSIONS Small target dose differences were found between plans using different collimation systems, which may be compensated for by adjusting the Iris collimator sizes to ensure similar dose distributions. The differences in the doses to the critical structures between the collimation systems were insignificant. After adjusting the Iris collimator sizes and re-commissioning the planning system, patients can be safely switched from the Iris collimator to the fixed cone collimator without replanning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose distributions of high-precision radiotherapy treatment: A comparison between the CyberKnife and TrueBeam systems

Background: Several high-precision stereotactic radiation therapy modalities are currently used in clinical settings. We aimed to evaluate whether the CyberKnife (CK) or TrueBeam (TB) radiation treatment systems were more appropriate for treating targets of various morphologies according to the physical properties of each device.  Materials and Methods: Spheres (diameter = 5–50 mm), as well as ...

متن کامل

COMP Report: CPQR technical quality control guidelines for CyberKnife® Technology

The Canadian Organization of Medical Physicists (COMP), in close partnership with the Canadian Partnership for Quality Radiotherapy (CPQR) has developed a series of Technical Quality Control (TQC) guidelines for radiation treatment equipment. These guidelines outline the performance objectives that equipment should meet in order to ensure an acceptable level of radiation treatment quality. This...

متن کامل

SU-E-T-642: Safety Procedures for Error Elimination in Cyberknife Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT).

PURPOSE Cyberknife system is used for providing stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) hypofractionation scheme. The whole treatment delivery is based on live imaging of the patient. The minor error made at any stage may bring severe radiation injury to the patient or damage to the system itself. Several safety measures were taken to make the system safer...

متن کامل

The Cyberknife ® M 6 TM Radiosurgery System Jeffrey

Lancaster General Health is the first institution in the United States to have the next generation CyberKnife made by Accuray Inc., the M6 series (Fig. 1). The CyberKnife utilizes non-invasive stereotactic radiosurgery to deliver precise, high doses of radiation to targets anywhere in the body. Recent studies have shown that stereotactic radiosurgery offers high rates of tumor control with mini...

متن کامل

WE-G-BRB-09: CyberKnife Patient Specific QA Using a 4D Cylindrical Diode Array System.

PURPOSE To examine and facilitate the feasibility of the ArcCheck cylindrical diode array system as a patient specific QA device for CyberKnife radiosurgery delivery. METHODS There is an obvious necessity for CyberKnife robotic radiosurgery patient QA procedures for hypofractionated treatment of larger planned treatment volumes (PTV), e.g. prostate. This need will increase when the future Cyb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part17  شماره 

صفحات  -

تاریخ انتشار 2012