Clinical decision support of therapeutic drug monitoring of phenytoin: measured versus adjusted phenytoin plasma concentrations

نویسندگان

  • Matthew D. Krasowski
  • Louis E. Penrod
چکیده

BACKGROUND Therapeutic drug monitoring of phenytoin by measurement of plasma concentrations is often employed to optimize clinical efficacy while avoiding adverse effects. This is most commonly accomplished by measurement of total phenytoin plasma concentrations. However, total phenytoin levels can be misleading in patients with factors such as low plasma albumin that alter the free (unbound) concentrations of phenytoin. Direct measurement of free phenytoin concentrations in plasma is more costly and time-consuming than determination of total phenytoin concentrations. An alternative to direct measurement of free phenytoin concentrations is use of the Sheiner-Tozer equation to calculate an adjusted phenytoin that corrects for the plasma albumin concentration. Innovative medical informatics tools to identify patients who would benefit from adjusted phenytoin calculations or from laboratory measurement of free phenytoin are needed to improve safety and efficacy of phenytoin pharmacotherapy. The electronic medical record for an academic medical center was searched for the time period from August 1, 1996 to November 30, 2010 for patients who had total phenytoin and free phenytoin determined on the same blood draw, and also a plasma albumin measurement within 7 days of the phenytoin measurements. The measured free phenytoin plasma concentration was used as the gold standard. RESULTS In this study, the standard Sheiner-Tozer formula for calculating an estimated (adjusted) phenytoin level more frequently underestimates than overestimates the measured free phenytoin relative to the respective therapeutic ranges. Adjusted phenytoin concentrations provided superior classification of patients than total phenytoin measurements, particularly at low albumin concentrations. Albumin plasma concentrations up to 7 days prior to total phenytoin measurements can be used for adjusted phenytoin concentrations. CONCLUSIONS The results suggest that a measured free phenytoin should be obtained where possible to guide phenytoin dosing. If this is not feasible, then an adjusted phenytoin can supplement a total phenytoin concentration, particularly for patients with low plasma albumin.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DETERMINATION OF PHA RMACOKINETIC PARAMETERS OF PHENYTOIN IN IRANIAN EPILEPTIC PATIENTS

Adjustment of phenytoin dosage in patients is very difficult due to its nonlinear metabolism and patient to patient variation in its kinetics. It has been recommended that the dosage of phenytoin should be adjusted according to its plasma concentration and requirements of the patients. Therefore, the present study was carried out to identify the various factors which may influence the plas...

متن کامل

Evidence-based implementation of free phenytoin therapeutic drug monitoring.

BACKGROUND The majority of laboratories measure total phenytoin concentration for therapeutic drug monitoring. However, there are substantial interindividual variations in free phenytoin concentrations, the pharmacologically active component. METHODS We describe the process and data used to implement monitoring of free phenytoin only in an urban medical center. Over a 6-week period, total and...

متن کامل

Effect of Pioglitazone on Plasma Levels of Phenytoin in Rats

Introduction: Interaction between drugs represents a major clinical concern for health care professionals and their patients. Patients affected by both type 2 diabetes and epilepsy may be prescribed pioglitazone and an anti-epileptic drug such as phenytoin  concurrently. The aim of this study was to consider the interaction of pioglitazone with phenytoin in an experimental model. According to t...

متن کامل

Use of saliva in therapeutic drug monitoring.

We measured the concentrations of phenobarbital, phenytoin, primidone, ethosuximide, antipyrine, and caffeine in paired samples of saliva and plasma by gas chromatograph-mass spectrometer-computer (GC/MS/COM) and enzyme immunoassay. Mixed saliva was collected for the antipyrine and caffeine studies, parotid saliva for the phenobarbital, primidone, ethosuximide and phenytoin studies. The saliva/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012