Persistent interface fluid syndrome.

نویسندگان

  • Richard S Hoffman
  • I Howard Fine
  • Mark Packer
چکیده

We present an unusual case of persistent interface fluid that would not resolve despite normal intraocular pressure and corneal endothelial replacement with Descemet-stripping endothelial keratoplasty. Dissection, elevation, and repositioning of the laser in situ keratomileusis flap were required to resolve the interface fluid. Circumferential corneal graft-host margin scar formation acting as a mechanical strut may have been the cause of the intractable interface fluid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Co-existence of Two Rare Conditions: Oculo-Palato-Cerebral Syndrome and Congenital Chylothorax

Background: Oculo-palato-cerebral syndrome is an extremely rare condition characterized by various features, including low-birth weight, microcephaly, cerebral atrophy, mild-to-severe developmental delay, cleft palate, persistent hyperplastic primary vitreous, microphthalmia, small hands and feet, joint laxity, and large ears with thick helices. Diagnosis of this syndrome is based on the clinic...

متن کامل

Meconium aspiration syndrome in neonates

Perhaps the most significant changes in airway management over the recent years have been in the management of an infant delivered through meconium- stained amniotic fluid( MSAF). MSAF occurs in approximately 10℅ to 20℅ of all deliveries and increases to over 30℅ in deliveries after 42 weeks gestation. Meconium aspiration syndrome ( MAS) occurs in about 2℅ to 5℅ of these cases with a high morta...

متن کامل

Propagation of Waves at an Interface of Heat Conducting Elastic Solid and Micropolar Fluid Media

The present investigation is concerned with the reflection and transmission coefficients of plane waves at the interface of generalized thermoelastic solid half space and heat conducting micropolar fluid half- space. The amplitude ratios of various reflected and transmitted waves with various angle of incidence have been computed numerically and depicted graphically. Micropolarity and thermal r...

متن کامل

Numerical simulation of the fluid dynamics in a 3D spherical model of partially liquefied vitreous due to eye movements under planar interface conditions

Partially liquefied vitreous humor is a common physical and biochemical degenerative change in vitreous body which the liquid component gets separated from collagen fiber network and leads to form a region of liquefaction. The main objective of this research is to investigate how the oscillatory motions influence flow dynamics of partial vitreous liquefaction (PVL). So far computational fluid d...

متن کامل

گزارش یک مورد نادر بیماری مادرزادی: Persistent Mullerian Duct Syndrome (PMDS) در یک آقای 71 ساله

Persistent Mullerian Duct Syndrome in a 71-Year-Old Man, Case Report H. Salehi MD , M.R. Vatani Baf MD Received:27/06/06 Sent for Revision: 11/10/06 Received Revised Manuscript: 07/02/07 Accepted: 12/02/07 Background and Objective: Normal sexual differentiation occurs in the 6th embryonic week and in a normal embryonic life. Both wolffian and mullerian ducts are present until the onse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 34 8  شماره 

صفحات  -

تاریخ انتشار 2008