The novel assay method for nicotine metabolism to cotinine using high performance liquid chromatography.
نویسندگان
چکیده
Nicotine is the primary psychoactive component in tobacco. It is taken into the body by tobacco smoking, and mainly metabolized to cotinine in the hepatic cytochrme P450 (CYP) 2A6. The objective of this study was to develop a sensitive method for the determination of nicotine metabolism to cotinine using HPLC. The internal standard, trans-4'-carboxycotinine methyl ester was synthesized with a simple method. The nicotine and cotinine were separated completely and detected by C(18) 5-µm analytical column (L-column Octa decyl silyl (ODS), 150 mm × 4.6 mm i.d.) equipped with a C(18) 5-µm guard column (L-column ODS, 10 mm × 4.6 mm i.d.) and ultraviolet detection at 260 nm. The detection limit of the assay was 0.05 µM for cotinine (n=5, R.S.D) and 0.1 µM for nicotine. Thus the present results provided a sensitive and useful method for the determination of nicotine metabolism catalyzed by CYP2A6.
منابع مشابه
Liquid-chromatographic determination of nicotine and cotinine in urine from passive smokers: comparison with gas chromatography with a nitrogen-specific detector.
We describe a simple, sensitive, and specific high-performance liquid-chromatographic method with ultraviolet detection (256 nm) for the simultaneous analysis of nicotine and cotinine in urine of passive smokers. The analytes are extracted and purified from the complex and impure matrix in two stages; first, by liquid-liquid extraction and followed by solid-phase extraction (C2 column). We used...
متن کاملA Novel High Performance Liquid Chromatographic Method for Determination of Nystatin in Pharmaceutical Formulations by Box–Behnken Statistical Experiment Design
this study a novel High Performance Liquid Chromatography for the assay of nystatin in oral and vaginal tablets were optimized and validated using Box–Behnken experimental design. The method was performed in the isocratic mode on a RP-18 column (30 °C) using a mobile phase consisting of 0.05 M ammonium acetate buffer/ Methanol mixture (30:70) and a flow-rate of 1.0 ml/min. The method was valida...
متن کاملTrace Determination of Duloxetine in Human Plasma by a Novel Ionic Liquid-Based Ultrasound-Assisted In Situ Solvent Formation Microextraction and High-Performance Liquid Chromatography
For the first time, a novel and efficient ionic liquid-based ultrasound-assisted in-situ solvent formation microextraction (IL-UA-ISFME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) has been successfully developed for the determination of duloxetine (DLX) in human plasma. Herein, an environmentally-friendly hydrophobic ionic liquid (1-butyl-3-methylimidaz...
متن کاملA Novel High Performance Liquid Chromatographic Method for Determination of Nystatin in Pharmaceutical Formulations by Box–Behnken Statistical Experiment Design
this study a novel High Performance Liquid Chromatography for the assay of nystatin in oral and vaginal tablets were optimized and validated using Box–Behnken experimental design. The method was performed in the isocratic mode on a RP-18 column (30 °C) using a mobile phase consisting of 0.05 M ammonium acetate buffer/ Methanol mixture (30:70) and a flow-rate of 1.0 ml/min. The method was valida...
متن کاملCharacterization and comparison of nicotine and cotinine metabolism in vitro and in vivo in DBA/2 and C57BL/6 mice.
DBA/2 and C57BL/6 are two commonly used mouse strains that differ in response to nicotine. Previous studies have shown that the nicotine-metabolizing enzyme CYP2A5 differs in coumarin metabolism between these two strains, suggesting differences in nicotine metabolism. Nicotine was metabolized to cotinine in vitro by two enzymatic sites. The high-affinity sites exhibited similar parameters (Km, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chemical & pharmaceutical bulletin
دوره 59 3 شماره
صفحات -
تاریخ انتشار 2011