Dynamic 3-dimensional stress cardiac magnetic resonance perfusion imaging: detection of coronary artery disease and volumetry of myocardial hypoenhancement before and after coronary stenting.

نویسندگان

  • Robert Manka
  • Cosima Jahnke
  • Sebastian Kozerke
  • Viton Vitanis
  • Gerard Crelier
  • Rolf Gebker
  • Bernhard Schnackenburg
  • Peter Boesiger
  • Eckart Fleck
  • Ingo Paetsch
چکیده

OBJECTIVES The aim of this study was to establish a new, dynamic 3-dimensional cardiac magnetic resonance (3D-CMR) perfusion scan technique exploiting data correlation in k-space and time with sensitivity-encoding and to determine its value for the detection of coronary artery disease (CAD) and volumetry of myocardial hypoenhancement (VOLUME(hypo)) before and after percutaneous coronary stenting. BACKGROUND Dynamic 3D-CMR perfusion imaging might improve detection of myocardial perfusion deficits and could facilitate direct volumetry of myocardial hypoenhancement. METHODS In 146 patients with known or suspected CAD, a 3.0-T CMR examination was performed including cine imaging, 3D-CMR perfusion under adenosine stress and at rest followed by delayed enhancement imaging. Quantitative invasive coronary angiography defined significant CAD (≥ 50% luminal narrowing). Forty-eight patients underwent an identical repeat CMR examination after percutaneous stenting of at least 1 coronary lesion. The 3D-CMR perfusion scans were visually classified as pathologic if ≥ 1 segment showed an inducible perfusion deficit in the absence of delayed enhancement. The VOLUME(hypo) was measured by segmentation of the area of inducible hypoenhancement and normalized to left-ventricular myocardial volume (%VOLUME(hypo)). RESULTS The 3D-CMR perfusion resulted in a sensitivity, specificity, and diagnostic accuracy of 91.7%, 74.3%, and 82.9%, respectively. Before and after coronary stenting, %VOLUME(hypo) averaged to 14.2 ± 9.5% and 3.2 ± 5.2%, respectively, with a relative VOLUME(hypo) reduction of 79.4 ± 25.4%. Intrareader and inter-reader reproducibility of VOLUME(hypo) measurements was high (Lin's concordance correlation coefficient, 0.96 and 0.96, respectively). CONCLUSIONS The 3D-CMR stress perfusion provided high image quality and high diagnostic accuracy for the detection of significant CAD. The VOLUME(hypo) measurements were highly reproducible and allowed for the assessment of the treatment effect achievable by percutaneous coronary stenting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Whole-heart dynamic three-dimensional magnetic resonance perfusion imaging for the detection of coronary artery disease defined by fractional flow reserve: determination of volumetric myocardial ischaemic burden and coronary lesion location.

AIMS Dynamic three-dimensional-cardiac magnetic resonance (3D-CMR) perfusion proved highly diagnostic for the detection of angiographically defined coronary artery disease (CAD) and has been used to assess the efficacy of coronary stenting procedures. The present study aimed to relate significant coronary lesions as assessed by fractional flow reserve (FFR) to the volume of myocardial hypoenhan...

متن کامل

Relationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction

Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...

متن کامل

Coronary artery calcium (CAC) score – a prognostic tool in coronary artery disease?

Introduction: The aim of this study was to evaluate the impact of measurement of coronary artery calcification score (CAC) in patients with suspected coronary artery disease (CAD) and a normal myocardial perfusion scan. Methods: In a prospective study we measured the calcium score of 74 patients (29 m, 45 f, mean age 58.7 (m) and 64.4 (f)) with suspicion of CAD and a normal perfusion scan. In ...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

Detection of Cardiac Artery Disease by Using the DCAD (b) Module

Introduction: In patients with cardiac artery disease, a myocardial perfusion scan, which is a non-invasive method, is utilized. This study is conducted to develop an advantageous software applicable to quantitative myocardial SPECT perfusion. Material and Methods: Each cross-section of the left ventricle was segmented by applying a fuzzy clustering method. After obtaining the myocardial skelet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 57 4  شماره 

صفحات  -

تاریخ انتشار 2011